REPORTING AND ACKNOWLEDGING OF
FAULTS
Faults are acknowledged dependent on the se-
lected mode of operation (LOCAL or REMOTE)
and on the severity of the fault:
1.
Mode of operation
:
LOCAL
Silent diagnostic
:
Yes
or
No
Minor fault
In the
LOCAL
mode of operation, minor faults
are reported and acknowledged in the same
way and irrespective of whether
Yes
or
No
has
been selected for the silent diagnosis:
The fault is displayed on the screen and an-
nounced by the buzzer in the control cabinet.
- Depress the "QUIT" key on the
control panel (Fig. 1)
once.
The buzzer stops sounding.
The message continues to be
displayed and can be read in no
hurry.
- Depress "QUIT" once more.
The fault message is definitely
acknowledged.
The message is deleted from
the display and logged in the
faults list.
2.
Mode of operation
:
LOCAL
Silent diagnostic
:
Yes
or
No
Severe fault
In the
LOCAL
mode of operation, severe faults
are reported and acknowledged as described
under
1.
In addition, the control system is switched off.
Optional shutdown of the engine is also possi-
ble.
A severe fault can only be acknowledged from
LOCAL
.
ATTENTION:
RISK OF ACCIDENT AND DAMAGE
After shut-off by a severe fault, the
control system and, if applicable, also
the drive engine must be restarted.
ñ It is absolutely vital to have a
severe fault rectified before re-
starting. There is otherwise the
risk of irreparable damage to the
machine.
Fig. 1