SEL-487V Data Sheet
Schweitzer Engineering Laboratories, Inc.
26
Wavelength:
1300 nm
Source:
LED
Min. TX Power:
–19 dBm
Max. TX Power:
–14 dBm
RX Sensitivity:
–32 dBm
Sys. Gain:
13 dB
Time Inputs
IRIG-B Input—Serial Port 1
Input:
Demodulated IRIG-B
Rated I/O Voltage:
5 Vdc
Operating Voltage Range:
0–8 Vdc
Logic High Threshold:
2.8 Vdc
Logic Low Threshold:
0.8 Vdc
Input Impedance:
2.5 k
IRIG-B Input—BNC Connector
Input:
Demodulated IRIG-B
Rated I/O Voltage:
5 Vdc
Operating Voltage Range:
0–8 Vdc
Logic High Threshold:
2.2 Vdc
Logic Low Threshold:
0.8 Vdc
Input Impedance:
>1 k
Dielectric Test Voltage:
0.5 kVac
Operating Temperature
–40
to +85
C (–40
to +185
F)
Note:
LCD contrast impaired for temperatures below –20°C and above
+70°C. Stated temperature ranges not applicable to UL applications.
Humidity
5% to 95% without condensation
Weight (Maximum)
3U Rack Unit:
8.00 kg (17.5 lb)
4U Rack Unit:
9.8 kg (21.5 lb)
5U Rack Unit:
11.6 kg (25.5 lb)
Terminal Connection
Rear Screw-Terminal Tightening Torque, #8 Ring Lug
Minimum:
1.0 Nm (9 in-lb)
Maximum:
2.0 Nm (18 in-lb)
User terminals and stranded copper wire should have a minimum
temperature rating of 105°C. Ring terminals are recommended.
Wire Size and Insulation
Wire sizes for grounding (earthing), current, voltage, and contact
connections are dictated by the terminal blocks and expected load
currents. You can use the following table as a guide in selecting wire
sizes. The grounding conductor should be as short as possible and
sized equal to or greater than any other conductor connected to the
device, unless otherwise required by local or national wiring
regulations.
Type Tests
Installation Requirements
Overvoltage Category:
3
Pollution Degree:
2
Safety
Product Standards
IEC 60255-27:2013
IEEE C37.90-2005
21 CFR 1040.10
Dielectric Strength:
IEC 60255-27:2013, Section 10.6.4.3
2.5 kVac, 50/60 Hz for 1 min: Analog
Inputs, Contact Outputs, Digital Inputs
3.6 kVdc for 1 min: Power Supply,
Battery Monitors
2.2 kVdc for 1 min: IRIG-B
1.1 kVdc for 1 min: Ethernet
Impulse Withstand:
IEC 60255-27:2013, Section 10.6.4.2
IEEE C37.90-2005
Common Mode:
±1.0 kV: Ethernet
±2.5 kV: IRIG-B
±5.0 kV: All other ports
Differential Mode:
0 kV: Analog Inputs, Ethernet,
IRIG-B, Digital Inputs
±5.0 kV: Standard Contact Outputs,
Power Supply Battery Monitors
+5.0 kV: Hybrid Contact Outputs
Insulation Resistance:
IEC 60255-27:2013, Section 10.6.4.4
>100 M
@ 500 Vdc
Protective Bonding:
IEC 60255-27:2013, Section 10.6.4.5.2
<0.1
@ 12 Vdc, 30 A for 1 min
Object Penetration:
IEC 60529:2001 + CRGD:2003
Protection Class: IP30
Max Temperature of Parts
and Materials:
IEC 60255-27:2013, Section 7.3
Flammability of Insulating
Materials:
IEC 60255-27:2013, Section 7.6
Compliant
Electromagnetic (EMC) Immunity
Product Standards:
IEC 60255-26:2013
IEC 60255-27:2013
IEEE C37.90-2005
Surge Withstand Capability
(SWC):
IEC 61000-4-18:2006 + A:2010
IEEE C37.90.1-2012
Slow Damped Oscillatory, Common and
Differential Mode:
±1.0 kV
±2.5 kV
Fast Transient, Common and Differential
Mode:
±4.0 kV
Electrostatic Discharge
(ESD):
IEC 61000-4-2:2008
IEEE C37.90.3-2001
Contact:
±8 kV
Air Discharge:
±15 kV
Connection Type
Min. Wire Size
Max. Wire Size
Grounding (Earthing)
Connection
14 AWG (2.5 mm
2
)
N/A
Current Connection
16 AWG (1.5 mm
2
)
10 AWG (5.3 mm
2
)
Potential (Voltage)
Connection
18 AWG (0.8 mm
2
)
14 AWG (2.5 mm
2
)
Contact I/O
18 AWG (0.8 mm
2
)
10 AWG (5.3 mm
2
)
Other Connection
18 AWG (0.8 mm
2
)
10 AWG (5.3 mm
2
)