16
EASY-MAG-Series | Version 2.01
Operation
9.1 Installation conditions
The device has been designed for indoor and outdoor
use and must be installed and operated in a dry environ-
ment.
The ambient air in which the welder is used should be
below + 40 ° C and low in humidity. The ambient air must
be free from dust, acids, salts or concentrations of iron or
metal powders.
Select the installation location of the welding machine so
that the inlet and outlet of the cooling air is not obstructed
(forced circulation with fan, if available); At the same
time, make sure that there are no conductive dusts, cor-
rosive vapors, moisture and the like. a. be sucked.
There must be at least 250 mm free space around the
welding machine.
Ambient conditions must be adequate for IP21 protec-
tion.
9.2 Mains connection
Before the electrical connections are made, check that
the data on the nameplate of the welding machine match
the mains voltage and frequency at the installation site
The welder may only be connected to a power connector
that has a grounded neutral conductor.
9.3 Connections of the welding circuit
Connection to the gas bottle (if used)
ATTENTION MAGNETIC FIELD
Magnetic fields of power circuits can affect the func-
tion of pacemakers. Persons wearing vital electronic
devices of this type must consult with the physician
before traveling to areas where such welding equip-
ment is available.
Interference may occur in the following areas /
devices. For this, appropriate countermeasures must
be taken:
- Data transmission systems,
- Communication systems
- Control,
- Safety devices
- Calibration and measuring devices.
DANGER! ELECTRICAL VOLTAGE
Do not use the device outdoors in the rain!
ATTENTION!
The welder should be set up on a flat and sufficiently
stable surface to prevent it from slipping or tipping
over.
DANGER!
Danger of electrocution!
Contact with live components may cause mortal dan-
ger. Switched on electrical components can cause
uncontrolled movements and lead to serious injuries.
ATTENTIONG!
Work on the electrical installation and on the electri-
cal equipment may only be carried out by electrici-
ans!
Before starting any work on the installation and
connection to the power supply, the welding machine
must be switched off and disconnected from the
power supply.
CAUTION!
Before the following connections are made, make
sure that the welder is switched off and disconnected
from the power supply.
CAUTION!
When handling gas cylinders, the relevant safety
regulations must be observed. In particular, because
of the dangerously high internal pressure (up to 200
bar), gas bottles are to be protected against mechani-
cal damage, falling over and falling down, from war-
ming (max 50 ° C), from prolonged exposure to the
sun and from severe frost.
NOTE!
Interventions and repairs to pressure reducers are not
permitted due to the associated hazards. Defective
pressure reducers are to be sent to the service work-
shop.
Содержание EASY-MAG 171