Maintenance and care
04.00|1400904 NSP 140, NSP-S 140 |en-US
35
CAUTION
Risk of injury to persons and risk of damage to the clamping
module when opening the cover.
If the clamping module has to be disassembled, ship the module
to SCHUNK for repair.
The covers of the clamping modules are spring pre-loaded and
must only be removed by trained specialist personnel.
To ensure the quick-change pallet system operates perfectly, the
following instructions are to be observed:
Pressure medium: hydraulic oil, filtered (10 µm), viscosity 46 mm/s
at 40°C to 60°C, volumetric flow max. 9 l/min and compressed air
quality according to ISO 8573-1: 7:4:4.
•
Make sure that the contact surfaces of the interface are always
clean.
•
Always ensure that no chips of any kind enter the interface.
•
When machining, only use high-quality coolant emulsions with
anti-rust additives, as they are prescribed for use on machining
centers anyway.
•
Check the units at regular intervals (at least every two weeks or
after 1000 clampings). The system is functioning correctly if the
clamping slides and the lifting pins move smoothly at minimum
system pressure (12 bar).
•
Carry out regular visual/functional checks. In case of visible
damage or signs of malfunction, shut down the quick-change
pallet system immediately. The system may only be
commissioned again once the faults have been removed. For
example, by replacing the damaged unit.
•
If a used module is exchanged for a new module, additional
clamping rings in mint condition must be used.