Maintenance
24
03.00 | TCU-P | Assembly and Operating Manual | en | 389462
6 Maintenance
6.1 Notes
Original spare parts
Use only original spare parts of SCHUNK when replacing spare and
wear parts.
6.2 Maintenance intervalls
NOTICE
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
•
Reduce the lubricant intervals accordingly.
at
Maintenance work
100 -
50
125 -
150
200 -
240
4
3
2
Treat all grease areas with lubricant,
Lubricants/Lubrication points (basic
lubrication)
4
3
2
Clean all parts thoroughly, check for damage
and wear, if necessary replace seals and
wearing parts,Oil or grease external steel
parts,
4
3
2
Replace shear pads,
6.3 Lubricants/Lubrication points (basic lubrication)
SCHUNK recommends the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point
Lubricant
Metallic sliding surfaces
microGLEIT GP 360
All seals
Renolit HLT 2
Bores on the piston
Renolit HLT 2