Maintenance
03.00 | TCU-P | Assembly and Operating Manual | en | 389462
25
6.4 Disassembly and assembly
6.4.1 Variant with locking (MV)
Position of the item numbers
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
Ø
Detach cable connections.
Ø
Remove the compressed air line.
Ø
Remove product from handling device.
NOTE
Housing-top (22) and adapter plate are aligned to each other,
using centering sleeves (50).
Ø
Remove screws (51) and separate product form the adapter
plate.
Ø
Remove screws (52) from the housing-top (02).
WARNING
Risk of injury due to spring forces!
The cylinder piston is under spring tension.
Carefully disassemble the product.
Ø
Remove screws (53) and remove bolt (09).
Ø
Separate housing top (22) from flange bottom (01).
Ø
Unscrew screws (49) and remove cylinder cover (04).
Ø
Remove cylinder piston (03) from the housing-top (02)
Ø
Remove screws (52) from the flange-bottom (01) and replace
shear pads (15).