![SCHUNK TANDEM KSF3 100 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/schunk/tandem-ksf3-100/tandem-ksf3-100_assembly-and-operating-manual_1215805032.webp)
Maintenance and care
32
02.00 | KSF3, KSF3-LH, KSF3-F | Assembly and Operating Manual | en |
1467140
Additionally for the KSF3-F variant:
Remove screw (68). Pull out the positioning
bolt (10) via its extraction thread with a screw
as far as the stop.
Pull the base jaw (9) out of the housing.
Variant "PM" also includes the O-ring (44).
Variant "PM" also includes O-ring (44),
monitoring piece (7) and compression springs
(26).
The monitoring element is adjusted and
secured with the set-screws (61, 63).
Caution! The monitoring piece is under spring
pre-load and is installed directionally oriented
for each base jaw! See detail views for jaw 1
and jaw 2!
Maintenance
• Clean all disassembled parts thoroughly and check for damage
and wear.
•
Treat all sliding surfaces with lubricant
•
Replace the seals of the monitoring if necessary
Assembly
Assembly is done in the reverse order of disassembly. In doing so,
observe the following:
•
Pay attention to the mounting position of the base jaws (item 2)
and the chuck piston (item 3).
•
Observe the tightening torques for the screws