Monitoring functions of the jaw stroke positions do not work
properly
Possible cause
Solution(s)
Monitoring pieces in the base jaws not
positioned exactly
Readjust monitoring piece for the required
Pressure change due to clamping
stroke too low
Adjust clamping stroke to the workpiece to >0.3
mm/jaw
Seals damaged
Replace seals in cover and adapter
plate