Technical data
3
Technical data
Installation position
any
Operating temperature
+5°C to +60°C
Noise emission [dB(A)]
≤ 70
Pressure medium
Compressed air, compressed air quality according to ISO
8573-1: 7:4:4
Max. speed
100
RPM
Designation
KSF3
100
160
250
Stroke per jaw [mm]
2
3
5
Clamping force range* [kN]
7 - 12
20 - 30
37 - 50
Opening pressure [bar]
6 - 9
6 - 9
6 - 9
Repeat accuracy** [mm]
0.01
0.01
0.02
Max. jaw height [mm]
60
60
150
Weight [kg]
4.3
12.5
39.4
Designation
KSF3-LH
100
160
250
Stroke per jaw [mm]
6
8
15
Clamping force range without turbo* [kN]
3 - 5
9 - 15
14 - 21
Clamping force range with turbo (6 bar)*
[kN]
8 - 11
22 - 34
33 - 46
Opening pressure [bar]
6 - 9
6 - 9
6 - 9
Max. turbo pressure [bar]
6
6
6
Repeat
accuracy** [mm]
0.01
0.01
0.02
Max. jaw height [mm]
150
200
500
Weight [kg]
4.4
12.7
39.6
Designation
KSF3-F
100
160
250
Stroke per jaw [mm]
4
6
10
Clamping force range* [kN]
7 -12
20 - 30
37 - 50
Opening pressure [bar]
6 - 9
6 - 9
6 - 9
Repeat accuracy** [mm]
0.01
0.01
0.02
Max. jaw height [mm]
60
60
150
Weight [kg]
4.3
12.6
39.4