21
Mounting of the
mounting kit
Proximity switch
Proximity switch
1
2
Cutout for
inserting the T-nuts
Attachment set SPG 100: ID number 0300765
Designation
Quantity
Control cam
1
Slot nut
2
Bracket
2
Screw
2
Countersunk screw
4
Ø
Fasten the control cam (3) on the base jaw (1) with the screws
(2).
Ø
Push both the T-nuts (7) into the T-groove of the guide bead (4).
Ø
Fasten both the brackets (6) to the two T-nuts (7) with the
countersunk screws (5), so that the brackets (6) can still be
shifted in the T-groove.
Ø
Shift the brackets (6) to the indicated position (see following
illustration).