Maintenance
08.00 | PZN-plus | Assembly and Operating Manual | en | 0389374
43
7.2 Maintenance intervals
NOTICE
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
•
Reduce the lubricant intervals accordingly.
Interval (million cycles)
for PZN-plus
Maintenance work
40 - 160 200 - 300 380
10
5
0.05 Clean all parts thoroughly, check for
damage and wear, if necessary replace
seals and wearing parts,
Disassembly and assembly
[
}
45].
The seals are in the enclosed sealing
kit.,
Sealing kit
[
}
8].
10
5
0.05 Treat all grease areas with lubricant,
Lubricants/greasing areas (basic lubrica-
tion)
[
}
44].
Oil or grease bare outside steel parts.