Technical data
08.00 | PZN-plus | Assembly and Operating Manual | en | 0389374
17
3 Technical data
Designation
PZN-plus
Pressure medium
Compressed air, compressed
air quality according to ISO
8573-1:7 4 4
Nominal working pressure [bar]
6
Minimum pressure [bar]
without gripping force maintenance
with gripping force maintenance
2.5
4
Max. pressure [bar]
without gripping force maintenance
with gripping force maintenance
Force intensified version (KVZ)
8
6.5
6
Pressure range for air purge [bar]
0.5 - 1
More technical data is included in the catalog data sheet.
Whichever is the latest version.
Environmental and operating conditions
Designation
PZN-plus
Ambient temperature [°C]
min.
max.
+5
+90 / (V/HT: +130)
IP protection class *
40 / (SD: 64)
Noise emission [dB(A)]
≤ 70
* For use in dirty ambient conditions (e.g. sprayed water, vapors,
abrasion or processing dust) SCHUNK offers corresponding
product options as standard. SCHUNK also offers customized