Maintenance
32
08.00 | PFH 150- 300 | Assembly and Operating Manual | en | 389270
6 Maintenance
6.1 Notes
Original spare parts
Use only original spare parts of SCHUNK when replacing spare and
wear parts.
6.2 Maintenance and lubrication intervals
CAUTION
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
•
Reduce the lubricant intervals accordingly.
Size
150 - 300
Interval [Mio. cycles]
1.5
6.3 Lubricants/Lubrication points (basic lubrication)
SCHUNK recommends the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point
Lubricant
Metallic sliding surfaces
Molykote BR 2 plus
All seals
Renolit HLT 2
Sliding surfaces within the
cylinder
Renolit HLT 2