5.3.2 Switch-off hysteresis for magnetic switches
Sensors MMS 22, MMS-P 22, MMS 22-PI1 and MMS 22-PI2
The smallest detectable difference in stroke is defined in the
following table:
The smallest detectable difference in stroke based on the nominal stroke
For grippers with X mm
nominal stroke per jaw
Min. query range per jaw/
min. queried stroke difference per jaw
X ≤ 5 mm
30% of the nominal stroke per jaw
X > 5 mm to X ≤ 10 mm
20% of the nominal stroke per jaw
X > 10 mm
10% of the nominal stroke per jaw
Example:
Product with 7 mm nominal stroke per jaw
7 mm * 20% = 1.4 mm
5.3.3 Mounting programmable magnetic switch MMS-PI2
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
5.3.3.1 Size MPG-Plus 25 / 25 IS – 50
For this size, there is a bracket in vertical direction mounted by default.
Ø
Loosen the screws at the bracket.
Ø
Move the sensor into to the bracket up to the stop.
Ø
Tighten the screws at the bracket.
Ø
Fasten the senor using a threaded pin.
Tightening torque: 10 Ncm
Ø
Check the protrusion of sensor L1, see table "adjustment
dimension".
Ø
Adjust the sensor, see assembly and operating manual of the sensor.
Protrusion of the sensor to be mounted