Troubleshooting
18
04.00 | LOG | Assembly and Operating Manual | en | 389509
5 Troubleshooting
5.1 Product does not move?
Possible cause
Corrective action
Pressure drops below minimum.
Component part defective.
Replace the gripper completely.
Make sure that the product was only used in
the context of its defined application
parameters
15].
5.2 The product does not travel through the entire stroke?
Possible cause
Corrective action
Dirt deposits between the end stops
Clean the product.
Pressure drops below minimum.
Check air supply.
Mounting surface is not sufficiently flat.
Check the evenness of the mounting surface.
Component part defective.
Replace the gripper completely.
5.3 Product opens or closes abruptly?
Possible cause
Corrective action
Compressed air lines blocked.
Check compressed air lines of damage.
5.4 The gripping force drops?
Possible cause
Corrective action
Compressed air can escape.
Check seals, replace product if necessary.
Pressure drops below minimum.
Check air supply.
5.5 Product does not achieve the opening and closing times?
Possible cause
Corrective action
Compressed air lines are not installed
optimally.
Check compressed air lines.
Inner diameters of compressed air lines are
of sufficient size in relation to compressed
air consumption.
Keep compressed air lines between the
product and directional control valve as
short as possible.
Flow rate of valve is sufficiently large
relative to the compressed air consumption.