Troubleshooting
26
04.00 | LGZ | Assembly and Operating Manual | en | 389192
5 Troubleshooting
5.1 Product is not moving
Possible cause
Corrective action
Base jaws jam in housing, e.g. mounting
surface is not sufficiently even.
Check the evenness of the mounting surface.
Mechanical connection
[
}
18]
Loosen the mounting screws of the product
and actuate the product again.
Pressure drops below minimum.
Check air supply.
Pneumatic connection
[
}
19]
Compressed air lines switched.
Check compressed air lines.
Pneumatic connection
[
}
19]
Proximity switch defective or set incorrect.
Readjust or change sensor.
Unused air connections open.
Close unused air connections.
Flow control valve closed.
Open the flow control valve.
Component part defective.
Replace component or send it to SCHUNK
for repair.
5.2 The module does not travel through the entire stroke?
Pneumatic connection
[
}
19]
Mechanical connection
[
}
18]
5.3 Module opens or closes abruptly?
Possible cause
Corrective action
Compressed air lines are blocked
Check the compressed air lines for crushing
or damage.
Mounting surface is not even enough
Check the levelness of the bolting surface.
Flow control valve is missing or not set
correctly
Install and adjust flow control valve.
Load too high
Review permissible weight and length of the
jaws.
Mechanical connection
[
}
18]