Assembly
18
04.00 | LGZ | Assembly and Operating Manual | en | 389192
4 Assembly
4.1 Mechanical connection
WARNING
Warning: Risk of injury when the machine/system moves unex-
pectedly!
Remove the energy supplies before starting with assembly and
adjustments.
Make sure that no residual energy remains in the system.
Check the evenness
of the bolting surface
The values relate to the entire bolting surface.
Requirements for levelness of the bolting surface (Dimensions in mm)
Diameter
Permissible unevenness
< 100
< 0.02
> 100
< 0.05
Mounting
The module can be mounted from the front or the rear.
Assembly options