Maintenance and repair work
130
06.00 | LDN | Assembly and Operating Manual | en | GAS360925
7.12 Limit switches and reference switches
Mechanical limit switches and inductive reference switch
1
Limit switches, mechanical 2
Reference switch, inductive
3
Switching lug
4
Limit and reference switch
baseplate
5
Limit switch baseplate
6
Distance plate
7
Switching distance,
mechanical limit switch
8
Switching distance,
inductive reference switch
1. Unscrew the mounting screws of the switch baseplate (4/5).
2. Unscrew the mounting screws of the switch (1/2) and remove
the switch.
3. Install the new switch and adjust the switching distance (7/8).
4. Fit the switch (1/2) and baseplate (4/5)
5. Perform a test run.
Содержание LDN G Series
Страница 1: ...Montage und Betriebsanleitung LDN Linearmotorachse Assembly and Operating Manual LDN Linear Motor Axis...
Страница 2: ...deutsch 3 english 75 2 06 00 LDN Montage und Betriebsanleitung de en GAS360925...
Страница 3: ...Original Betriebsanleitung Montage und Betriebsanleitung LDN Linearmotorachse...
Страница 22: ...Technische Daten 22 06 00 LDN Montage und Betriebsanleitung de GAS360925 3 1 Typen bersicht...
Страница 42: ...Montage 42 06 00 LDN Montage und Betriebsanleitung de GAS360925 Pneumatikplan Pneumatikplan f r Haltebremsen...
Страница 75: ...Translation of Original Operating Manual Assembly and Operating Manual LDN Linear Motor Axis...
Страница 93: ...Technical Data 3 1 Overview of types 93 06 00 LDN Assembly and Operating Manual en GAS360925...
Страница 113: ...Assembly Pneumatic diagram Pneumatic diagram for holding brake 113 06 00 LDN Assembly and Operating Manual en GAS360925...
Страница 147: ......
Страница 148: ...Folgen Sie uns I Follow us 09 2020 2020 SCHUNK GmbH Co KG 06 00 LDN Montage und Betriebsanleitung de en GAS360925...