Start-up
34
04.00 | FTN-AXIA | Commissioning instructions | en | 1366833
Table column
Description
Comment
Counts
Displays the load value to be compared with
the measured value of the FT sensor. This
value is displayed in the units of the active
configuration after the "Apply" button has
been clicked.
To determine the Counts value to use from a
value in user units, the value in user units
must be multiplied by Counts per force (or
Counts per torque, if applicable).
IMPORTANT! Comparison levels are stored
as count values and only change when the
user enters new count values. Changing the
configuration or the force units or the
torque units does not change or adjust the
count values.
Example:
Desired load: 6.25 N
Unit: N (from
Configuration page)
Counts per force value:
1000000 (from
Configuration page)
Counts
= Desired load × Counts
per force
= 6.25 N × 1000000
counts/N
= 6250000 counts
Units
Displays the count value in the units of the active configuration. This
value is only updated after the "Apply" button has been clicked. The
list shows the bit pattern that each threshold statement number
represents.
• 0: 0x00000001
• 1: 0x00000002
• 2: 0x00000004
• 3: 0x00000008
• 4: 0x00000010
• 5: 0x00000020
• 6: 0x00000040
• 7: 0x00000080
• 8: 0x00000100
• 9: 0x00000200
• 10: 0x00000400
• 11: 0x00000800
• 12: 0x00001000
• 13: 0x00002000
• 14: 0x00004000
• 15: 0x00008000