Technical data
8
02.00 | FMS | Assembly and Operating Manual | en | 389074
3 Technical data
Electronic processor
Designation
FMS-A 1/2
Size
50 ... 125 ; 160 ... 380
Operating voltage [V]
Nominal voltage [VDC]
[Rated range]
18 - 30
24
[Reverse polarity protection]
Output signal * [V]
-5 ... +5
Current input [mA]
< 45
Ambient temperature [°C]
Min.
Max.
-10
+65
Accuracy **
±3% for ID 301 810
±5% for ID 301 811
Weight [kg]
0.38
IP rating
67 with inserted plug connector
and closed cover
* The output voltage is linear to the forces occurring at the gripper
fingers. The bandwidth of the output signal is not fully used by
each active intermediate jaw.
** Before measuring, a zero adjustment must be carried out.
More technical data is included in the catalog data sheet.
Whichever is the latest version.
The force measuring jaw and the passive intermediate jaw are
always adapted to the gripper: