Assembly
02.00 | FMS | Assembly and Operating Manual | en | 389074
13
5 Assembly
5.1 Mechanical installation of the measuring system
NOTICE
Property damage due to incorrect bending radius!
The product may get damaged if the cable's bending radius is less
than the minimum.
•
Static:
10 times the cable diameter.
•
Dynamic:
15 times the cable diameter.
Dimensions of the force/torque sensor system controller FMS-A1/ A2
1
Ø4.5 ( 2x) for mounting screw M4
Ø
Mounting the intermediate jaws on the base jaws of the
gripper.
Ø
Fasten the gripper fingers to the intermediate jaws.
The drilling pattern of the intermediate jaws corresponds to
that of the base jaws. This way, the gripper fingers can be
mounted on the intermediate jaw as well as on the base jaw.
Ø
Fasten the electronic processor using two M4 screws.
The distance from the electronic processor to the force
measuring jaws must not exceed the length of the cable
supplied.
NOTE
When screwing the force measuring adapter onto the gripper, and
the gripper finger to the force measuring adapter, the nominal
torque of the screws is to be observed.