Basic safety notes
03.00 | ERS 135 - 210 / 560V | Assembly and Operating Manual | en | 389064
9
2.5 Ambient conditions and operating conditions
Required ambient conditions and operating conditions
Incorrect ambient and operating conditions can make the product
unsafe, leading to the risk of serious injuries, considerable material
damage and/or a significant reduction to the product's life span.
• Make sure that the product is used only in the context of its
defined application parameters,
19].
2.5.1 Electromagnetic compatibility
The product meets the requirements of the EMC act of the inner-
European market, among other requirements. The product has
passed the EMC test as per the following standards:
Standard
Title
EN 61000-6-2
(2006)
EMC: Generic standard – Interference immunity
in industrial environments
EN 61000-6-3
(2011)
EMC: Generic standards - emitted interference
for living area, business and commercial areas
and small businesses
The product must be installed using interference-free cables and in
a way that meets EMC requirements in order to ensure
interference-free operation.
Interference
variables:
The electromagnetic compability with pulse-shaped inference
variables has been verified and confirmed according to the
following standards:
Standard
Title
EN 61000-4-2
(2008)
Test and measurement procedures - Testing the
interference immunity to discharging of static
electricity
EN 61000-4-4
(2008)
Test and measurements procedures - Testing the
interference immunity to fast transient electric
interference variables/burst
EN 61000-4-5
(2014)
Test and measurement procedures - Testing the
interference immunity to surge voltages