5.1.1.2 Installing the micro valve
Micro valve
NOTE
Always carry out the assembly of the micro valve in the following
order, for example to avoid unscrewing the screw cap from the
valve cartridge if an accessory is fitted subsequently.
Ø
Screw the hollow screw of the swivel fitting (1) lightly into the
pneumatic unit (5), without tightening.
Ø
Turn the swivel fitting (1) to the desired position and hold it
firmly.
Ø
Tighten the hollow screw of the swivel fitting (1) in this position,
maximum tightening torque 1.5 Nm.
Ø
Screw the valve cartridge (2) into the swivel fitting (1) as far as
possible, maximum tightening torque 3 Nm.
Ø
Screw the sound absorber (4) into the valve cover (3), maximum
tightening torque: 3 Nm.
Ø
Put the valve cover (3) on the cartridge (2) with the connection
cable in the required position.
Ø
Push the valve cover (3) onto the cartridge (2) and screw tight
with the knurled nut onto the cartridge (2), maximum torque:
3 Nm.
Ø
Connect the pneumatic hose to the pneumatic connection of
the swivel fitting (1).
Ø
Push the Y‐distributor onto the M8 plug of the connection cable
and screw tight.
Ø
Push the cable extension onto the Y‐distributor and screw tight.
Ø
Connect the cable extension to the electrical power supply,
42].
Ø
Route the connection cable and cable extension and secure.