Troubleshooting
05.00 | ELB | Montage- und Betriebsanleitung | en | GAS 376437
99
8 Troubleshooting
8.1 Product does not move
Possible cause
Corrective action
Electrical connection incorrect e.g. Phase
rotator.
Electrical connection according
specifications e.g. carry out circuit diagram.
Error in the drive controller.
See documentation for drive controller.
8.2 Product does not achieve the cycle times
Possible cause
Corrective action
Attachments on the product have too much
mass.
Check cycle time calculation.
Specifications made by control unit are not
correct.
Correct specifications.
Error in the drive controller.
See documentation for drive controller.
8.3 Product gets too hot
Possible cause
Corrective action
Temperature sensor not connected
properly.
Check electrical connection.
Attachments on the product have too much
mass.
Check cycle time calculation.
Error in the drive controller.
See documentation for drive controller.
Содержание ELB 70-H075
Страница 1: ...Montage und Betriebsanleitung Assembly and Operating Manual...
Страница 3: ...Montage und Betriebsanleitung ELB Linearmotorachse Assembly and Operating Manual ELB Linear motor axis...
Страница 4: ...2 05 00 ELB Montage und Betriebsanleitung GAS 376437 deutsch 3 english 53...
Страница 5: ...Original Betriebsanleitung Montage und Betriebsanleitung ELB Linearmotorachse...
Страница 43: ...Montage 05 00 ELB Montage und Betriebsanleitung de GAS 376437 41 Pneumatikplan Pneumatikplan f r Haltebremsen...
Страница 55: ...Translation of original operating manual Assembly and Operating Manual ELB Linear motor axis...
Страница 85: ...Assembly 05 00 ELB Montage und Betriebsanleitung en GAS 376437 83 6 1 2 1 PE ground M5 grounding screw...
Страница 107: ......