Technical data
01.00 | EGM | Assembly and Operating Manual | en | 389539
21
3.6 Basic data EGM B-L
Designation
EGM B-L
30-1x2
30-1x4
Dimension X x Y x Z [mm]
190 x 75 x 61 330 x 75 x 61
Weight [kg]
6.5
11.5
Magnetic surface [cm
2
]
36
72
Number of poles
2
4
Load capacity * for horizontal
magnetic surface [kg]
60
110
Load capacity * for vertical
magnetic surface [kg]
20
40
Minimum workpiece thickness [mm]
8
Max. activations/minute [RPM]
15
20
Increased product temperature **
at 5 / 15 activations per minute [°C]
15 / 35
12 / 32
Current input on activation/
deactivation [A]
3.1
6.5
Max. permissible product
temperature [° C]
+80
Ambient temperature [°C]
Min.
Max.
+5
+50
Air humidity [%]
Min.
Max.
30
80
Noise emission [dB(A)]
≤ 70
IP protection class
54
Permissible controller variant
ECG-C, ECG-W, ECG-R
Permissible controller size
ECG 02
Max. number EGM per controller
24
13
* Full load capacity can only be reached under ideal conditions
(material, workpiece density, surface, etc.). In case of
questions on dimensioning of load capacity, contact SCHUNK.
** Increased product temperature tested on material 1.0037
with 20 mm workpiece thickness, ground surface and
complete coverage of the magnetic surface.