Technical data
01.00 | EGM | Assembly and Operating Manual | en | 389539
19
3.5 Basic data EGM B-Q
Designation
EGM B-Q
50-1x2
50-1x4
50-2x2
Dimension X x Y x Z [mm]
170 x
95 x 61
290 x
95 x 61
170 x
150 x 61
Weight [kg]
5.5
13
8.5
Magnetic surface [cm
2
]
50
100
Number of poles
2
4
Load capacity * for horizontal
magnetic surface [kg]
75
175
Load capacity * for vertical
magnetic surface [kg]
30
70
Minimum workpiece thickness [mm]
12
14
Max. activations/minute [RPM]
20
8
Increased product temperature **
at 5 / 15 activations per minute [°C]
12 / 30
30 / 68
Current input on activation/
deactivation [A]
2.9
9.5
Max. permissible product
temperature [° C]
+80
Ambient temperature [°C]
Min.
Max.
+5
+50
Air humidity [%]
Min.
Max.
30
80
Noise emission [dB(A)]
≤ 70
IP protection class
54
Permissible controller variant
ECG-C, ECG-W, ECG-R
Permissible controller size
ECG 02
Max. number EGM per controller
25
7