Basic safety notes
10
03.00 | EGI | Assembly and Operating Manual | en | 1396645
2.6.1 Environmental conditions
Transport and storage requirements
For transport and storage of product in original packaging, the
following requirements apply:
• Loading and unloading with mechanical aids
• Ambient temperature from -40 °C to +70 °C
• Air humidity up to max. 85%
Operational requirements
The following requirements apply for operation of the product:
• Ambient temperature from +5 °C to +55 °C
• Air humidity up to max. 65%
According to DIN EN 60068-2-6 and DIN EN 60068-2-27, in
accordance with EN 60721-3-2 and EN 60721-3-3, the product was
subjected to a vibration and shock inspection during transport and
in operation with respect to the ambient influences and
withstands the required loads.
The product may only be used in the following locations if
additional measures are taken:
• In locations with a high level of ionizing radiation
• In locations with difficult operating conditions, e.g. due to
caustic fumes, gases, oils or chemicals
• In facilities requiring special monitoring, e.g. in particularly at-
risk areas
• In applications during which the product is exposed to
unacceptably severe knocking or vibrations Suitable measures
must be taken to reduce the amplitude or acceleration of such
disturbances. Vibration-damping or vibration-absorbing systems
are to be used in such cases.
The product must also not be used in potentially explosive zones.