Commissioning
01.00 | ECG | Assembly and Operating Manual | en | 389769
31
6 Commissioning
Ø
Observe all notes in this chapter when commissioning and
making adjustments on the system side of the product.
DANGER
Danger from electric voltage!
Touching live parts may result in death.
•
Switch off the power supply before any assembly, adjustment
or maintenance work and secure against being switched on
again.
•
Only qualified electricians may perform electrical installations.
•
Check if de-energized, ground it and hot-wire.
•
Cover live parts.
DANGER
Risk of injury due to magnetic fields!
The integrated electric permanent magnets can pose a risk to
people with an active or passive implant.
•
People with pacemakers or active or passive implants are
prohibited from entering the area of the magnetic field.
WARNING
Danger of crushing due to magnetically attracted tools!
Tools may be attracted by the strong magnetic fields and cause
severe injuries.
•
Only work in deactivated and demagnetized state.
WARNING
Risk of burns through contact with hot surfaces!
Surfaces of components can heat up severely during operation.
Skin contact with hot surfaces causes severe burns to the skin.
•
For all work in the vicinity of hot surfaces, wear safety gloves.
•
Before carrying out any work, make sure that all surfaces have
cooled down to the ambient temperature.