Maintenance
25.00 | DPZ-plus | Assembly and Operating Manual | en | 389035
49
Ø
Do not screw the screw (42) completely into the cover (12). The
gap between the side cover (12) and the housing (1) should be
approximately divided in half.
Ø
Allow the gripper to run for about 20 cycles so that the side
covers (12) can be centered with respect to the base jaws (2/7)/
intermediate jaws (13), the gasket (14) and the housing (1).
Ø
Tighten the screws (42) to fasten the side cover (12).
Ø
Apply a strip of Plast-o-Seal along the side cover (12),
Position of the Plast-o-Seal (previous version)
53].
Ø
Insert the seal (37) into the housing (1).
Ø
Screw the cover plate (5) on tight with the screws (47).