Assembly and installation
02.00 | PW V6 | Assembly and operating manual | en | 389670
33
Ø
Pull the metric cable fitting (6) just far enough over the shrink
hose so that the individual wires remain visible.
Ø
Screw the metric cable fitting (6) to the cover (4) or the
connection cap (2).
Ø
Place the cover (4) on the connection cap (2) and screw it tight.
5.6 Combination of multiple products
Combination of multiple products, PROFIBUS and CAN bus
When multiple products are combined, the signals are looped
through from Product n to Product n+1. The wires from Terminal
X2 of the product are clamped in Terminal X1 of Product n+1.
The terminating resistor for CAN bus or PROFIBUS must be set on
the last product,
28].