Schumacher PST-1000 Скачать руководство пользователя страница 12

12

LIMITED WARRANTY

SCHUMACHER ELECTRIC CORPORATION, 801 BUSINESS CENTER DRIVE, MOUNT PROSPECT, ILLINOIS 60056-2179  MAKES
THIS LIMITED WARRANTY TO THE ORIGINAL PURCHASER AT RETAIL OF THIS PRODUCT. THIS LIMITED WARRANTY IS
NOT TRANSFERABLE.

Schumacher Electric Corporation warrants this battery tester for one year from date of purchase at retail against defective material
or workmanship. If such should occur, the unit will be repaired or replaced at the option of the manufacturer. It is the obligation of the
purchaser to forward the unit together with the original sales receipt, transportation and/or mailing charges prepaid to the manufac-
turer or its authorized representative.

This limited warranty is void if the product is misused, subjected to careless handling, or repaired by anyone other than the
manufacturer or its authorized representative.

The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any
warranty for consequential damages.

THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND THE MANUFACTURER NEITHER ASSUMES NOR AUTHORIZES
ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS EXPRESS LIM-
ITED WARRANTY. THE MANUFACTURER MAKES NO WARRANTY OF MERCHANT ABILITY OR FITNESS FOR PURPOSE OF
THIS PRODUCT AND EXPRESSLY EXCLUDES SUCH FROM THIS LIMITED WARRANTY.

SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR
LENGTH OF IMPLIED WARRANTY SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM
STATE TO STATE.

WARNING: 

Handling the cord on this product or cords associated with accessories sold with this product, will expose you to lead,

a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. 

Wash hands after handling

.

Содержание PST-1000

Страница 1: ...em Analyzer For 6 and 12 Volt Batteries 00 99 000443 1004 Questions Call Customer Service 1 800 621 5485 Send Warranty Product Repairs To Customer Returns P O Box 280 1025 E Thompson Avenue Hoopeston...

Страница 2: ...s included in this instruction guide and or the use of this automotive test product 10 Avoid electrical shocks caused by getting too close to live ignition wires or touching the coil TACH terminal A p...

Страница 3: ...and then begins sounding an audible beep and the Time Out lamp illuminates Both are reminders to turn off the load before removing or moving the battery cable clamps from the battery ANALYZER HOOK UP...

Страница 4: ...mpere Hour rating is known multiply the value by 3 to obtain the load For example a 200 Ah battery times 3 equals a 600 amperes load 3 BATTERY WATTS When only the battery rating in watts is known then...

Страница 5: ...nd carry a lifetime supply of electrolyte One type has the negative and positive terminals on the top and another has them on the side The side terminal type have threaded terminal connections which a...

Страница 6: ...ith ignition disabled crank engine and watch voltmeter to see that reading is not too high 4 Test Conclusion A good circuit will typically have less than 0 2 volt drop If okay go to Solenoid Control S...

Страница 7: ...winding continuity Then with engine stopped and ignition switch in RUN position If lamp stays on look for a short to ground on the disconnected wire If lamp stays off Check alternator field circuit fo...

Страница 8: ...e voltage regulator case ground to the alternator case ALTERNATOR CASE BATTERY CHASSIS SOLENOID RELAY REGULATOR CASE Figure 9 3 Run the engine at idle but first momentarily boost it to 2000 Rpm to be...

Страница 9: ...or even a single 24 volt battery Six volt batteries may be Load tested individually or in pairs if wired in series NEVER attempt to Load test a 24 volt battery with the PST 1000 The two most common c...

Страница 10: ...onnections in the cranking circuit Refer to the PST 1000 manual for troubleshooting information In a 24 volt circuit acceptable voltage drops are twice those for 12 volt circuits If testing of the mag...

Страница 11: ...charging and starting circuits are included in the PST 1000 manual Always refer to the engine manufacturer s instructions before performing any tests with which you may be unfamiliar ANALYZER CARE Wh...

Страница 12: ...acturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND TH...

Отзывы: