10

3.

Place the Amp Probe around the starter cable.

4.

Connect the external volts positive lead to the positive terminal
of the starter.

5.

Connect the external volts negative lead to the starter ground.

6.

Set the Volts Selector to External Volts ±199.9 volt range.

   Figure 11

Transformer Rectifier Starter Draw Test

STARTER

CHASSIS

BATTERY

CRANKING

BATTERY

ALT

TR

 

++

 

-

 

+

 

-

12V LOADS

MAG

SW

S

+ 24V

+ 12V

Figure 12

Series-Parallel Switch Starter Draw Test

STARTER

CHASSIS

BATTERY

SWITCH

ALT

 

++

 

-

12V LOADS

CRANKING

BATTERY

 

+

 

-

SERIES

PARALLEL

SWITCH

Crank the engine for 15 seconds, and note the cranking amper-
age reading. Also, watch to see that the starter voltage stays
above 19.2 volts. Never crank the engine longer than 30 sec-
onds. Wait at least two minutes for the starter to cool, if the test
is to be repeated.

In some medium-duty applications, where there are two banks of
CRANKING batteries, it may be necessary to connect the Amp
Probe around both wires at once to read total current draw. If the
wires are too far apart for the Amp Probe, simply measure the
draw in each wire and add the results.

TEST CONCLUSIONS

The circuit is good if cranking speed was satisfactory and battery
voltage at the starter stayed above 19.2 volts. Slow cranking speed
is often caused by poor connections in the cranking circuit. Refer
to the PST-1000 manual for troubleshooting information. In a 24
volt circuit, acceptable voltage drops are twice those for 12 volt
circuits. If testing of the magnetic switch, solenoid, and other
components reveal no problems, the starter should be replaced.

ALTERNATOR OUTPUT CURRENT TEST

TRANSFORMER RECTIFIER

There are two separate output wires. A 12 volt, high current out-
put feeding the CHASSIS battery and a 24 volt, low current out-
put, feeding the CRANKING battery. (See diagram below).

TEST PROCEDURE

12 Volt Output

1.

Connect the Analyzer’s load cables across the CHASSIS
battery.

2.

Place the Amp Probe around the 12 volt output wire.

Figure 13

Transformer-Rectifier Alternator Output Test-12V

STARTER

CHASSIS

BATTERY

CRANKING

BATTERY

ALT

TR

 

++

 

-

 

+

 

-

12V LOADS

MAG

SW

S

+ 24V

+ 12V

3.

Set the Volts Selector to Battery Volts.

4.

Run the engine at about 2000 RPM.

5.

Turn the Load ON and increase until the battery voltage is
between 12.5 and 13.5 volts while reading the output
amperage.

6.

Turn the Load OFF and reduce RPM.

TEST CONCLUSIONS

1.

If the Diode/Stator lamp stayed on during the output test,
replace the alternator.

2.

If the amperage abruptly decreased during the test, check
for a loose belt.

3.

If output was less than 90% of rating, see PST-1000 manual
for output resistance test procedures.

Figure 14

Transformer-Rectifier Alternator Output Test-24V

STARTER

CHASSIS

BATTERY

CRANKING

BATTERY

ALT

TR

 

++

 

-

 

+

 

-

12V LOADS

MAG

SW

S

+ 24V

+ 12V

Содержание PST-1000

Страница 1: ...em Analyzer For 6 and 12 Volt Batteries 00 99 000443 1004 Questions Call Customer Service 1 800 621 5485 Send Warranty Product Repairs To Customer Returns P O Box 280 1025 E Thompson Avenue Hoopeston...

Страница 2: ...s included in this instruction guide and or the use of this automotive test product 10 Avoid electrical shocks caused by getting too close to live ignition wires or touching the coil TACH terminal A p...

Страница 3: ...and then begins sounding an audible beep and the Time Out lamp illuminates Both are reminders to turn off the load before removing or moving the battery cable clamps from the battery ANALYZER HOOK UP...

Страница 4: ...mpere Hour rating is known multiply the value by 3 to obtain the load For example a 200 Ah battery times 3 equals a 600 amperes load 3 BATTERY WATTS When only the battery rating in watts is known then...

Страница 5: ...nd carry a lifetime supply of electrolyte One type has the negative and positive terminals on the top and another has them on the side The side terminal type have threaded terminal connections which a...

Страница 6: ...ith ignition disabled crank engine and watch voltmeter to see that reading is not too high 4 Test Conclusion A good circuit will typically have less than 0 2 volt drop If okay go to Solenoid Control S...

Страница 7: ...winding continuity Then with engine stopped and ignition switch in RUN position If lamp stays on look for a short to ground on the disconnected wire If lamp stays off Check alternator field circuit fo...

Страница 8: ...e voltage regulator case ground to the alternator case ALTERNATOR CASE BATTERY CHASSIS SOLENOID RELAY REGULATOR CASE Figure 9 3 Run the engine at idle but first momentarily boost it to 2000 Rpm to be...

Страница 9: ...or even a single 24 volt battery Six volt batteries may be Load tested individually or in pairs if wired in series NEVER attempt to Load test a 24 volt battery with the PST 1000 The two most common c...

Страница 10: ...onnections in the cranking circuit Refer to the PST 1000 manual for troubleshooting information In a 24 volt circuit acceptable voltage drops are twice those for 12 volt circuits If testing of the mag...

Страница 11: ...charging and starting circuits are included in the PST 1000 manual Always refer to the engine manufacturer s instructions before performing any tests with which you may be unfamiliar ANALYZER CARE Wh...

Страница 12: ...acturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND TH...

Отзывы: