Schumacher 9275A-PE Скачать руководство пользователя страница 5

5

1373-401

FIGURE 1: CONNECT NEGATIVE BATTERY CLAMP

TO 24-INCH CABLE END

BATTERY

POSITIVE

NEGATIVE

24", 6 GUAGE
CABLE

POWER
CORD

TO GROUNDED
POWER OUTLET

+

-

BATTERY CHARGER

1.

Check polarity of battery posts. Battery case will be marked
by each post: POSITIVE (POS, P, +) and NEGATIVE (NEG,
N, -). 

NOTE:

 The positive battery post usually has a larger

diameter than the negative post.

2.

Attach a 24-inch long (or longer)  6-gauge (AWG) insulated
battery cable to NEGATIVE (NEG, N, -) battery post.
(Purchase cable separately.)

3.

Connect POSITIVE (RED) charger  clamp to POSITIVE (POS,
P, +) battery post. Rock clamp back and forth to make good
connection.

4.

Position yourself and free end of 24-inch cable as far away
from battery as possible. Then connect NEGATIVE (BLACK)
charger clamp to free end of cable. 

 WARNING: 

 Do not face

battery when making final connection. Rock clamp back
and forth to make a good connection.

FIGURE 1 shows the connection.

5.

Plug charger AC cord into 120 volt outlet.

6.

Select automatic or manual charging, see Charger
Controls.

7.

When battery is fully charged, unplug charger from AC
power source.

8.

When battery is fully charged and charger is unplugged,
(1) remove clamp from end of Negative end of cable, and
(2) remove clamp from Positive battery post, in that order.

9.

Clean and store battery charger.

1.

Position AC power cord and DC charging cords to reduce risk
of damage by hood, door, or moving engine parts.

2.

Stay clear of fan blades, belts, pulleys, and other parts that
can cause injury.

3.

Check polarity of battery posts. Battery case will be marked
by each post: POSITIVE (POS, P, +) and NEGATIVE (NEG,
N, -). 

NOTE: 

The positive battery post usually has a larger

diameter than the negative post.

4.

Determine which post of battery is grounded (connected)
to chassis. 

NOTE: 

The negative post is normally grounded.

GROUND

(NEG)

FIGURE 2: CONNECTION TO NEGATIVE

GROUNDED BATTERY

NEGATIVE GROUNDED POST

5A. For negative-grounded vehicle, connect POSITIVE (RED)

clamp from battery charger to POSITIVE (POS, P, +)
ungrounded post of battery. Connect NEGATIVE (BLACK)
clamp to vehicle chassis or engine block away from battery.
Connect to a heavy-gage metal part of the frame or engine
block.

WARNING: 

Do not connect clamp to carburetor, fuel lines, or

sheet-metal body parts. 

NOTE: 

Attach clamps to battery

post and twist or rock back and forth several times to make
a good connection. This tends to keep clamps from slipping
off terminals and helps to reduce risk of sparking.

FIGURE 2 shows connections for a negative-grounded battery.

POSITIVE GROUNDED POST

5B. For positive-grounded vehicle, connect NEGATIVE (BLACK)

clamp  from battery charger to NEGATIVE (NEG, N, -)
ungrounded post of battery. Connect POSITIVE (RED) clamp
to vehicle chassis or engine block away from battery.
Connect to a heavy-gauge metal part of the frame or engine
block.

6.

Plug charger AC cord into a grounded 120 volt outlet.

7.

Select either automatic or manual, see Charger Controls.

8.

When battery is fully charged, unplug charger from AC power
source.

9.

Remove charger clamps from (1) chassis and (2) battery
post, in that order.

10.  Clean and store battery charger.

NOTE:

 Charger will hum when clamps are removed from

battery and power cord is still plugged into electrical outlet.

OPERATING INSTRUCTIONS: CHARGING BATTERY IN VEHICLE

When charging battery in vehicle, take care to determine the battery type and which pole is grounded. To reduce risk of a spark near
battery, follow these steps when battery is inside vehicle. 

 WARNING: 

A spark near the battery may cause battery explosion.

Содержание 9275A-PE

Страница 1: ...t using battery 2 Use battery charger on LEAD ACID type rechargeable bat teries only such as used in autos trucks tractors airplanes vans RV s trolling motors etc Charger is not intended to supply pow...

Страница 2: ...vice Sparking may cause an explosion 7 Always operate battery charger in an open well ventilated area 8 NEVER smoke or allow a spark or flame in the vicinity of the battery or engine Batteries generat...

Страница 3: ...Meter to determine the state of charge When using the Manual mode the charging must be frequently monitored Selector Switch When the switch is set to the Engine Start position the Automatic and Manua...

Страница 4: ...tteries These heavy duty batteries are used in boats construction equipment sump pumps etc They are nor mally marked DEEP CYCLE on the outside of the case MANUAL VS AUTOMATIC CHARGING In theAUTOMATIC...

Страница 5: ...han the negative post 4 Determine which post of battery is grounded connected to chassis NOTE The negative post is normally grounded GROUND NEG FIGURE 2 CONNECTION TO NEGATIVE GROUNDED BATTERY NEGATIV...

Страница 6: ...the AC outlet is live by plugging in a lamp A Unplug the charger and check the connections at the battery B Wait the 4 minutes of rest time and try again C The thermal protector may have tripped and n...

Страница 7: ...of the purchaser to forward the unit together with proof of purchase transportation and or mailing charges prepaid to the manufacturer or its authorized representative This limited warranty is void i...

Страница 8: ...VE THESE INSTRUCTIONS 801 BUSINESS CENTER DRIVE MOUNT PROSPECT ILLINOIS 60056 2179 Send Warranty Product Repairs to 1025 E Thompson Avenue Hoopeston IL 60942 0280 Call Customer Service if you have que...

Страница 9: ...ue sea absolutamente necesario El uso de un cable de extensi n incorrecto podr a resultar en incendio o choque el ctrico Si debe usarse un cable de extensi n aseg rese que Las clavijas del enchufe del...

Страница 10: ...Opere siempre el cargador de bater a en un rea abierta y bien ventilada 8 NUNCA fume ni permita chispas o llamas en la vecindad de la bater a o del motor Las bater as generan gases explosivos PREPARA...

Страница 11: ...el indicador de Charge Complete no funciona en el modo Manual Hay que usar el Amperiometro para verificar el estado de la carga Al usar el modo Manual el proceso de cargar requiere monitoreo frecuente...

Страница 12: ...punto el cargador ha dejado de cargar a la bater a pero aun hace zumbido mientras no se apague la energ a el ctrica TIPOS DE BATERIA Se pueden cargar tres tipos de bater as de cido de plomo con este...

Страница 13: ...RTENCIA Conecte primero el poste puesto a tierra al instalar nuevamente la bater a INSTRUCCIONES DE OPERACION PARA CARGAR DE LA BATERIA FUERA DEL VEH CULO FIGURA 1 CONECTE LA PINZANEGATIVA DELACUMULAD...

Страница 14: ...riente Problema Soluci n 1 El medidor no muestra lectura A Confirme que el cargador est enchufado en la tomacorriente CA B Conecte una l mpara en la tomacorriente CA para confirmar que est viva C Revi...

Страница 15: ...ada de la prueba de compra al fabricante o a su representante autorizado con el costo del transporte o de env o por correo ya pagado Esta garant a limitada no es v lida si el producto ha sido usado i...

Страница 16: ...STRUCCIONES Para reparaci n del producto baja garant a env elo a 1025 E Thompson Hoopeston IL 60942 0280 Para m s informaci n comun quese al Dep de Servicios al Cliente 1 800 621 5485 ELECTRICCORPORAT...

Отзывы: