CHARGE RATE

The charger will automatically adjust the 

charging current, based on battery size, 

in order to charge the battery completely, 

efficiently and safely. 

BATTERY CHARGING TIMES

Times are based on a 50% discharged  

battery and may change, depending on age 

 

and condition of battery.

AUTOMATIC CHARGING MODE

When the Automatic Charge is performed, 

the charger switches to the maintain 

mode automatically after the battery is 

charged. 

ABORTED CHARGE

If charging cannot be completed normally, 

charging will abort. When charging aborts, 

the charger’s output is shut off and the 

CHARGING

 

 

(yellow/orange) LED will 

flash. To reset after an aborted charge, 

unplug the charger from the AC outlet, 

wait a few moments and plug it back in.

DESULFATION MODE

Desulfation could take 8 to 10 hours.  

If desulfation fails, charging will abort and 

the 

CHARGING

 

 

(yellow/orange) LED

 

will flash.

COMPLETION OF CHARGE

Charge completion is indicated by the 

CHARGED 

 (green) LED. When 

pulsing, the charger has switched to the 

maintain mode of operation. 

MAINTAIN MODE  

(FLOAT-MODE MONITORING)

When the CHARGED 

 (green) LED is 

pulsing, the charger has started maintain 

mode. In this mode, the charger keeps the 

battery fully charged by delivering a small 

current when necessary. If the charger 

has to provide its maximum maintain 

current for a continuous 12 hour period, 

it will go into abort mode (see Aborted 

Charge section). This is usually caused by 

a drain on the battery or the battery could 

be bad. Make sure there are no loads on 

the battery. If there are, remove them. If 

there are none, have the battery checked 

or replaced. 

MAINTAINING A BATTERY

The SC-1200A-CA and SSC-1500A-CA 

maintain both 6 and 12 volt batteries, 

keeping them at full charge. 

NOTE:

 The maintain mode technology 

allows you to safely charge and maintain 

a healthy battery for extended periods 

of time. However, problems with the 

battery, electrical problems in the 

vehicle, improper connections or other 

unanticipated conditions could cause 

excessive current draws. As such, 

occasionally monitoring your battery and 

the charging process is required.

USING THE BATTERY VOLTAGE 

TESTER 

1. 

With the charger unplugged from the 

AC outlet, connect the charger to the 

battery following the instructions given 

in previous sections.

2. 

Plug the charger AC power cord into 

the AC outlet.

3. 

If necessary, press the BATTERY 

TYPE button until the correct type is 

indicated.

4. 

Read the voltage on the digital display. 

Keep in mind that this reading is only a 

battery voltage reading; a false surface 

charge may mislead you. Compare the 

reading to the chart below.

6 V Battery 

Voltage 

Reading

12 V Battery 

Voltage 

Reading

Battery 

Condition

6.4 or more

12.8 or more

Charged

6.1 to 6.3

12.2 to 12.7

Needs 

charging

Less than 6.1 Less than 12.2

Discharged

POWER-UP IDLE TIME LIMIT

If no button is pressed within 10 minutes 

after the battery charger is first powered 

up, the charger will automatically switch 

from tester to charger if a battery is 

connected. In that case, the charger will 

be set to charge at the 3A rate and AGM 

battery type (SC-1200A-CA) or gel cell 

battery type (SSC-1500-CA).

TESTING AFTER CHARGING

After the unit has been changed from 

tester to charger (by selecting a charge 

rate), it remains a charger. To change the 

battery charger back to a tester, press the 

CHARGING RATE button until all charge 

rate LEDs are off.

Содержание SC-1200A-CA

Страница 1: ...E This manual will explain how to use the battery charger safely and effectively Please read and follow these instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUAL DEL USUARIO Y LEALO...

Страница 2: ...USE THE CHARGER b To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery R...

Страница 3: ...ff position and removing AC cord from electric outlet Never allow clips to touch each other 5 2 Attach clips to battery and chassis as indicated in the sections 6 and 7 6 FOLLOW THESE STEPS WHEN BATTE...

Страница 4: ...k or electrocution NOTE Pursuant to Canadian Regulations use of an adapter plug is not allowed in Canada Use of an adapter plug in the United States is not recommended and should not be used USING AN...

Страница 5: ...ge voltages on this type of cell are lower than those for other styles of lead acid battery This is probably the most sensitive cell in terms of adverse reactions to overvoltage charging Gel batteries...

Страница 6: ...hecked or replaced MAINTAINING A BATTERY The SC 1200A CA and SSC 1500A CA maintain both 6 and 12 volt batteries keeping them at full charge NOTE The maintain mode technology allows you to safely charg...

Страница 7: ...bad Have it checked or replaced F02 The charger cannot desulfate the battery The battery could not be desulfated have it checked or replaced F03 The battery was unable to reach the full charge voltage...

Страница 8: ...ting The charger is equipped with Auto Voltage Detection which automatically detects the voltage and charges the battery No problem this is normal 14 SPECIFICATIONS SC 1200A CA Input Voltage 120V AC 6...

Страница 9: ...g repaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied...

Страница 10: ...ducir el riesgo de descarga el ctrica desenchufe el cargador del tomacorriente antes de intentar llevar a cabo cualquier actividad de mantenimiento o limpieza El simple apagado de los controles no red...

Страница 11: ...pila hasta que el cido de la bater a alcance el nivel especificado por el fabricante de la bater a No provoque derrames En lo que concierne a bater as que no cuentan con tapas extra bles para pilas t...

Страница 12: ...eh culo o al bloque motor alejado de la bater a No conecte al carburador l neas de combustible o cuerpos met licos Conecte a una pieza met lica de calibre grueso del marco o del bloque motor 6 7 Al de...

Страница 13: ...nrede todos los cordones y extienda los cables antes de usar el cargador de bater as 10 PANEL DE CONTROL INDICADORES LEDS LED CLAMPS REVERSED pinzas invertido rojo parpadea Las conexiones est n invers...

Страница 14: ...e recarga de este tipo de c lulas son m s bajos que los de los otros estilos de la bater a de plomo cido sta es probablemente la c lula m s sensible en t rminos de las reacciones adversas a la carga d...

Страница 15: ...corriente cuando corresponda Si el cargador tiene que funcionar al m ximo en corriente continua de mantenimiento a un periodo de 12 horas se transladar al Modo de Interrumpir v ase la secci n Carga A...

Страница 16: ...nservarse en un lugar fresco y seco No lo enrede las pinzas en el mango no las una ni en metal tampoco sujete a los cables 13 LOCALIZACI N Y RESOLUCI N DE PROBLEMAS Y CODIGOS DE ERROR Codigos de Error...

Страница 17: ...isar la bater a No puedo seleccionar los 6 o 12 Voltios El Cargador est equipado con Detecci n de Auto Voltaje que autom ticamente detecta el voltaje y carga la bater a No hay problema es una condici...

Страница 18: ...onas que nos sean el Fabricante o si esta unidad es revendida a trav s de un vendedor minorista no autorizado El Fabricante no realiza ninguna otra garant a incluidas a t tulo enunciativo las garant a...

Страница 19: ...e Purchased____________________ Date of Purchase__________ Store Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For...

Отзывы: