background image

 

4

 

7.  FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE

A SPARK NEAR THE BATTERY MAY 

CAUSE A BATTERY EXPLOSION. TO 

REDUCE THE RISK OF A SPARK NEAR 

THE BATTERY:

7.1 

Check polarity of battery posts. POSITIVE 

(POS, P, +) battery post usually has a larger 

diameter than NEGATIVE (NEG, N, –) post.

7.2 

Attach at least a 24-inch-long 6-gauge 

(AWG) insulated battery cable to 

NEGATIVE (NEG, N, –) battery post.

7.3 

Connect POSITIVE (RED) charger clip to 

POSITIVE (POS, P, +) post of battery.

7.4 

Position yourself and free end of cable as 

far away from battery as possible – then 

connect NEGATIVE (BLACK) charger clip 

to free end of cable.

7.5 

Do not face battery when making final 

connection.

7.6 

When disconnecting charger, always do 

so in reverse sequence of connecting 

procedure and break first connection 

while as far away from battery as 

practical.

7.7 

A marine (boat) battery must be removed 

and charged on shore. To charge it on 

board requires equipment specially 

designed for marine use. 

8.  GROUNDING AND AC POWER CORD CONNECTIONS 

This battery charger is for use on a 

nominal 120 volt circuit. The plug must 

be plugged into an outlet that is properly 

installed and grounded in accordance with 

all local codes and ordinances. The plug 

pins must fit the receptacle (outlet). Do 

not use with an ungrounded system.

DANGER:

 Never alter the AC cord or 

plug provided – if it does not fit the outlet, 

have a proper grounded outlet installed 

by a qualified electrician. An improper 

connection can result in a risk of an 

electric shock or electrocution. 

NOTE:

 Pursuant to Canadian 

Regulations, use of an adapter plug 

is not allowed in Canada. Use of an 

adapter plug in the United States is not 

recommended and should not be used.

USING AN EXTENSION CORD

The use of an extension cord is not 

recommended. If you must use an 

extension cord, follow these guidelines:

• 

Pins on plug of extension cord must be 

the same number, size, and shape as 

those of plug on charger.

• 

Ensure that the extension cord is 

properly wired and in good electrical 

condition.

• 

Wire size must be large enough for 

the AC ampere rating of charger, as 

specified:

Length of cord (feet)

25

50

100 150

AWG* size of cord

18

18

16

14

*AWG-American Wire Gauge

9.  ASSEMBLY INSTRUCTIONS

9.1 

Remove all cord wraps and uncoil the cables prior to using the battery charger. 

10. CONTROL PANEL

LED INDICATORS

 

CLAMPS REVERSED (red) LED 

flashing: 

The connections are reversed.

 

CHARGING (yellow/orange) LED lit:

  

The charger is charging the battery.

 

CHARGING (yellow/orange) LED 

flashing:

 The charger is in abort mode.

 

CHARGED (green) LED pulsing:

  

The battery is fully charged and the 

charger is in maintain mode.

NOTE:

 See the Operating Instructions 

section for a complete description of the 

charger modes.

DIGITAL DISPLAY

The display will show the battery 

VOLTAGE when the charger is not 

charging a battery. When it goes 

into charging mode, the display will 

automatically change to 

ON

 (to show 

charging has started) and then show the 

percent-of-charge of the battery being 

charged and either 6 or 12 (the voltage of 

the battery, determined by the charger). If 

you manually stop the charging process 

(by pressing the CHARGING RATE 

button) before the battery is fully charged, 

the display will show 

OFF

.

Содержание SC-1200A-CA

Страница 1: ...E This manual will explain how to use the battery charger safely and effectively Please read and follow these instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUAL DEL USUARIO Y LEALO...

Страница 2: ...USE THE CHARGER b To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery R...

Страница 3: ...ff position and removing AC cord from electric outlet Never allow clips to touch each other 5 2 Attach clips to battery and chassis as indicated in the sections 6 and 7 6 FOLLOW THESE STEPS WHEN BATTE...

Страница 4: ...k or electrocution NOTE Pursuant to Canadian Regulations use of an adapter plug is not allowed in Canada Use of an adapter plug in the United States is not recommended and should not be used USING AN...

Страница 5: ...ge voltages on this type of cell are lower than those for other styles of lead acid battery This is probably the most sensitive cell in terms of adverse reactions to overvoltage charging Gel batteries...

Страница 6: ...hecked or replaced MAINTAINING A BATTERY The SC 1200A CA and SSC 1500A CA maintain both 6 and 12 volt batteries keeping them at full charge NOTE The maintain mode technology allows you to safely charg...

Страница 7: ...bad Have it checked or replaced F02 The charger cannot desulfate the battery The battery could not be desulfated have it checked or replaced F03 The battery was unable to reach the full charge voltage...

Страница 8: ...ting The charger is equipped with Auto Voltage Detection which automatically detects the voltage and charges the battery No problem this is normal 14 SPECIFICATIONS SC 1200A CA Input Voltage 120V AC 6...

Страница 9: ...g repaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied...

Страница 10: ...ducir el riesgo de descarga el ctrica desenchufe el cargador del tomacorriente antes de intentar llevar a cabo cualquier actividad de mantenimiento o limpieza El simple apagado de los controles no red...

Страница 11: ...pila hasta que el cido de la bater a alcance el nivel especificado por el fabricante de la bater a No provoque derrames En lo que concierne a bater as que no cuentan con tapas extra bles para pilas t...

Страница 12: ...eh culo o al bloque motor alejado de la bater a No conecte al carburador l neas de combustible o cuerpos met licos Conecte a una pieza met lica de calibre grueso del marco o del bloque motor 6 7 Al de...

Страница 13: ...nrede todos los cordones y extienda los cables antes de usar el cargador de bater as 10 PANEL DE CONTROL INDICADORES LEDS LED CLAMPS REVERSED pinzas invertido rojo parpadea Las conexiones est n invers...

Страница 14: ...e recarga de este tipo de c lulas son m s bajos que los de los otros estilos de la bater a de plomo cido sta es probablemente la c lula m s sensible en t rminos de las reacciones adversas a la carga d...

Страница 15: ...corriente cuando corresponda Si el cargador tiene que funcionar al m ximo en corriente continua de mantenimiento a un periodo de 12 horas se transladar al Modo de Interrumpir v ase la secci n Carga A...

Страница 16: ...nservarse en un lugar fresco y seco No lo enrede las pinzas en el mango no las una ni en metal tampoco sujete a los cables 13 LOCALIZACI N Y RESOLUCI N DE PROBLEMAS Y CODIGOS DE ERROR Codigos de Error...

Страница 17: ...isar la bater a No puedo seleccionar los 6 o 12 Voltios El Cargador est equipado con Detecci n de Auto Voltaje que autom ticamente detecta el voltaje y carga la bater a No hay problema es una condici...

Страница 18: ...onas que nos sean el Fabricante o si esta unidad es revendida a trav s de un vendedor minorista no autorizado El Fabricante no realiza ninguna otra garant a incluidas a t tulo enunciativo las garant a...

Страница 19: ...e Purchased____________________ Date of Purchase__________ Store Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For...

Отзывы: