background image

 

7

 

To convert Reserve Capacity to Amp Hours, divide Reserve Capacity by 2, and add 16:

Example:

Amp Hour Rating = Reserve Ca 16

                                             2

NOTE:

 The Reserve Capacity can be obtained from the battery specification sheet or the 

owner’s manual.

To calculate the time needed for a charge:

1. 

Find the percent of charge needed (a battery at 50 percent charge that will be 

charged to 100 percent needs another 50 percent (.5).

2. 

Multiply the Amp Hour Rating by the charge needed (.5) and divide by the charger 

setting (5 amps).

3. 

Multiply the results by 1.25, and you will have the total time needed, in hours,  

to bring the battery to a full charge.

4. 

Add an additional hour for a deep-cycle battery.

Example:

Amp Hour Rating x % of charge needed x 1.25 = hours of charge

                 Charger Setting

100 (AH Rating) x .50 (charge needed) x 1.25 = 12.5 hours

              5 (Charger Setting)

100 x .50 x 1.25 = 12.5

       5

A 100-Ampere Hour Battery must charge for 12 ½ hours when using the above example. 

15.  MAINTENANCE INSTRUCTIONS

15.1 

Before performing maintenance, unplug and disconnect battery charger (see sections 6.7 

and 7.6).

15.2 

After use, unplug charger and use a dry cloth to wipe all battery corrosion and other dirt 

or oil from terminals, cords, and the charger case. 

15.3 

Have any cracked or frayed cables replaced by an authorized service person.

15.4 

Servicing does not require opening the unit, as there are no user-serviceable parts. 

16.  STORAGE INSTRUCTIONS

16.1 

Store charger unplugged, in an upright position. Cord will still conduct electricity until it is 

unplugged from the outlet. 

16.2 

Store inside, in a dry, cool place (unless you’re using an on-board Marine Charger).

16.3 

Do not store clips on handle, clipped together, on or around metal, or clipped to cables. 

17.  TROUBLESHOOTING

LED GUIDE/PROBLEM

POSSIBLE CAUSE

SOLUTION

The charger is plugged in but 

the POWER ON (red) LED is 

not lit.

No power at the AC receptacle.

Poor electrical connection.

The battery charger is not 

functioning properly.

Check for open fuse or circuit 

breaker supplying AC outlet.

Check power cord and 

extension cord for loose 

fitting plug.

Have battery checked.

The battery is connected and 

the POWER ON (red) LED 

is on, but the CHARGING 

(yellow) LED is not lit and 

charger is not charging.

Battery connectors are not 

making a good connection.

The battery is bad.

The battery charger is not 

functioning properly.

Check for poor connection 

at battery. Make sure 

connecting points are clean.

Have the battery checked by 

a qualified service person.

Have battery checked.

Содержание DSR INDUSTRIAL INC-2405A

Страница 1: ...low these instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUAL DEL USUARIO Y LEALO ANTES DE CADA USO En este manual le explica c mo utilizar el cargador de bater a de manera segura y...

Страница 2: ...w been dropped or otherwise damaged in any way take it to a qualified service person 1 8 Do not disassemble the charger take it to a qualified service person when service or repair is required Incorre...

Страница 3: ...autions while charging and recommended rates of charge 3 6 Determine the voltage of the battery by referring to the vehicle owner s manual and make sure that the output voltage selector switch is set...

Страница 4: ...ery post 7 3 Connect the POSITIVE RED charger clip to the POSITIVE POS P post of the battery 7 4 Position yourself and the free end of the cable you previously attached to the NEGATIVE NEG N battery p...

Страница 5: ...3 4 5 11 MOUNTING CHARGER TO A FLAT SURFACE Do not mount charger in a location with restricted air flow The area where the charger is to be fastened must be dry well ventilated and away from any comb...

Страница 6: ...seconds the CHARGING yellow LED will glow to show that charging has begun If none of the LEDs glow or if the CHARGING yellow LED does not glow refer to the troubleshooting section Charge time may var...

Страница 7: ...ion and other dirt or oil from terminals cords and the charger case 15 3 Have any cracked or frayed cables replaced by an authorized service person 15 4 Servicing does not require opening the unit as...

Страница 8: ...is intended for use with lead acid and gel cell batteries only Electrical Nominal Operating Voltage VAC 100 240 Input Voltage Range VAC 85 264 Input Current A rsm max 2 9 85V 60Hz Output Power W 120...

Страница 9: ...odified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied or statutory wa...

Страница 10: ...enchufe da ados reempl celos de inmediato 1 8 No manipule el cargador si ha recibido un golpe fuerte se ha ca do o da ado de cualquier modo ll velo a un t cnico calificado 1 9 No desarme el cargador...

Страница 11: ...la bater a y eliminar la corrosi n transportada por el aire No se toque los ojos nariz o boca 3 4 Agregue agua destilada en cada celda hasta que el cido de la bater a alcance el nivel especificado po...

Страница 12: ...chasis de veh culo o bloque del motor lejos de la bater a No conecte el sujetador al carburador a las mangueras de combustible o planchas de metal de la carrocer a Conecte a una parte met lica del cal...

Страница 13: ...iente Entrada de corriente Medida del cable segun la AWG Longitud del cable pies m De A no menos de 25 7 6 50 15 2 100 30 5 150 45 6 0 2 18 18 18 16 2 3 18 18 16 14 3 4 18 18 16 14 4 5 18 18 14 12 5 6...

Страница 14: ...argador 11 2 Coloque la parte posterior del cargador con la m nsula de montaje contra una superficie segura y plana 11 3 Monte el cargador en forma segura sobre una superficie plana con m nimo de pulg...

Страница 15: ...cargar totalmente su bater a primero hay que determinar el nivel de carga de la bater a con un hidr metro o un Probador de Porcentaje de Carga electr nico La tabla a continuaci n ser de ayuda en conve...

Страница 16: ...trica El cargador de bater as no funciona debidamente Vea si est abierto el fusible o disyuntor que provee al tomacorriente CA Revise los cordones de potencia y extensi n para enchufe flojo Haga exami...

Страница 17: ...lida Voltios CC nominal alcance 24 2 29 5 Mec nicas Estuche Aluminio Negro Anodizado Dimensiones pulgadas 7 Largo x 5 Ancho x 2 Alto Peso 1 80 libras Conexiones Entrada de Potencia CA Enchufe Macho C1...

Страница 18: ...nte o si esta unidad es revendida a trav s de un vendedor minorista no autorizado El Fabricante no realiza ninguna otra garant a incluidas a t tulo enunciativo las garant as expresas impl citas o lega...

Страница 19: ...e Purchased____________________ Date of Purchase__________ Store Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For...

Отзывы: