15. SPECIFICATIONS

Nominal input voltage ................................................................................. 12.8-13.2 VDC
Nominal output voltage .................................................................................. 110-125 VAC
Output frequency ............................................................................................. 60 Hz±3 Hz
Operating input voltage ............................................................................... 10.5-15.5 VDC
Continuous output power .............................................................................. Up to 1000 W
Surge output power (0.1 second) ...........................................................................2000 W
Waveform ..............................................................................................Modified sine wave
Maximum efficiency .....................................................................................................90%
Maximum no load current (at nominal input voltage) ...........................................0.60 ADC
Input overvoltage shutdown .............................................................................16±0.5 VDC
Input undervoltage alarm ..............................................................................10.5±0.5 VDC
Input low voltage shutdown..............................................................................10±0.5 VDC
Output power overload shutdown level ...........................................................1150±150 W
Internal fuse ............................................................................................................ 40A x 3
AC receptacles.................................................................................Two, NEMA 5-15 USA
USB port ................................................................................................................ One, 2A
Battery cables .......................................................................................One black, one red
Ground wire ....................................................................................................... One green

16. REPLACEMENT PARTS

Battery cable (black) .....................................................................................3899003407Z
Battery cable (red) ........................................................................................3899003408Z

17. BEFORE RETURNING FOR REPAIRS

If these solutions do not eliminate the problem,  

or for more information about troubleshooting,  

contact customer service for assistance:

[email protected]  

www.batterychargers.com

or call 1-800-621-5485 

Monday-Friday 7:00

am

 to 5:00

pm

 CST

For 

REPAIR OR RETURN

, contact Customer Service at 1-800-621-5485. 

DO NOT SHIP 

UNIT

 until you receive a 

RETURN MERCHANDISE AUTHORIZATION (RMA) 

number 

from Customer Service at Schumacher Electric Corporation.

Содержание BATTERY EXTENDER BE01257

Страница 1: ...CONSERVE ESTE MANUAL DEL USUARIO Y LEALO ANTES DE CADA USO En este manual le explica c mo utilizar el convertidor de manera segura y confiable Por favor lea y siga las siguientes instrucciones y prec...

Страница 2: ...e power converter to a 12V battery or power supply Do not attempt to connect the converter to any other power source including an AC power source Connecting to a 6V or 16V battery will cause damage to...

Страница 3: ...t runs on a motor the device goes through two stages 1 Start Up Requiring an initial surge of power commonly known as the starting or peak load 2 Continuous Operation Power consumption drops commonly...

Страница 4: ...1 Turn off and disconnect the converter 2 Locate the chassis ground screw on the back of the converter 3 Remove the outer hex nut and loosen the second hex nut 4 Attach the grounding wire s ring conne...

Страница 5: ...ve output cables to opposite ends of the bank Do not allow the output cables to touch one another 4 Test the voltages at the output cables to make sure that the battery bank is correctly wired 5 If th...

Страница 6: ...the USB port 2 Turn the USB device on 3 Reverse these steps when finished using the USB port WARNING The converter draws power even when the switch is OFF To avoid battery drain disconnect the conver...

Страница 7: ...oes not require opening the unit as there are no user serviceable parts All servicing should be performed by qualified service personnel 13 5 Store inside in a cool dry place out of the reach of child...

Страница 8: ...150 W Internal fuse 40A x 3 AC receptacles Two NEMA 5 15 USA USB port One 2A Battery cables One black one red Ground wire One green 16 REPLACEMENT PARTS Battery cable black 3899003407Z Battery cable r...

Страница 9: ...epaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied or...

Страница 10: ...cual puede llevar a una lesi n seria o la muerte 1 12 No coloque el convertidor sobre o cerca de ventilas de calefacci n radiadores u otras fuertes de calor o materiales inflamables 1 13 No coloque el...

Страница 11: ...Negativa del cable de la bater a Negra Termina la tierra y cable de tierra Conecta a tierra el convertidor para reducir la descarga el ctrica Protecci n t rmica Cuando el resistor t rmico supera los 8...

Страница 12: ...ecalentamiento Seno modificada de forma de onda producido por el convertidor Diagrama A Diagrama B Sinusoidal pura forma de onda t pico de la casa de la toma de CA IMPORTANTE Si usted esta usando el c...

Страница 13: ...dor l neas de combustible o cuerpos met licos Conecte a una pieza met lica de calibre grueso del marco o del bloque motor 4 Para desconectar el convertidor quite primero el terminal negativo y luego e...

Страница 14: ...tor del convertidor a la posici n de ON encendido I 3 La luz del indicador LED debe brillar VERDE verificando que el convertidor est recibiendo energ a 4 Cambie el interruptor de balanc n del converti...

Страница 15: ...positivo siendo operado con el convertidor Cuando sea posible recargar las bater as cuando no son m s del 50 de descargado Esto le da a las bater as de un ciclo de vida mucho m s larga que la recarga...

Страница 16: ...os componentes el ctricos internos 14 LOCALIZACI N Y SOLUCI N DE PROBLEMAS PROBLEMA CAUSA POSIBLE SOLUCI N Tensi n de salida baja o nula Mal contacto en las terminales El uso del tipo incorrecto de vo...

Страница 17: ...150 W Fusible interno 40 A x 3 Tomas de corriente CA Dos NEMA 5 15 USA Puerto USB Uno 2 A Cables de la bater a Uno negro uno rojo Cable de tierra Uno verde 16 PIEZAS DE REPUESTO Cable de bater a negr...

Страница 18: ...nos sean el Fabricante o si esta unidad es revendida a trav s de un vendedor minorista no autorizado El Fabricante no realiza ninguna otra garant a incluidas a t tulo enunciativo las garant as expresa...

Страница 19: ...e Purchased____________________ Date of Purchase__________ Store Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For...

Отзывы: