Schumacher Electric BATTERY EXTENDER BE01257 Скачать руководство пользователя страница 3

 

3

 

3.  CONVERTER LOCATION

3.1 

Never place unit directly above battery; 

gases from battery will corrode and 

damage the converter.

3.2 

Never allow battery acid to drip on unit 

when reading gravity or filling battery.

3.3 

Do not operate converter in a closed-in 

area or restrict ventilation in any way.

4.  FEATURES

• 

ON/OFF rocker switch

• 

LED indicator

 

Green indicates Power ON  

Red indicates Overload/Interruption  

in power

• 

12 Volt power cord

• 

120V standard AC outlets (2)

• 

USB port – 5V, 2.0A

• 

High-speed cooling fan 

To keep the converter cool, the fan speeds 

up as the load increases. The fan does 

not run when the converter is turned off. 

• 

Positive Battery Cable Terminal (Red)

• 

Negative Battery Cable Terminal 

(Black)

• 

Ground Terminal and ground wire 

Grounds converter, to protect against 

electrical shock.

• 

Thermal Protection 

When the thermal resistor exceeds  

80° C (176° F), the converter shuts 

down until it cools off, and then 

automatically restarts.

• Surge Protection

 

When the power input from the 

vehicle’s battery exceeds 16 volts, the 

converter shuts down. Once the voltage 

drops down to less than 14 volts, it 

automatically restarts.

• Low-Battery Protection

 

When the power input from the vehicle’s 

battery drops to below 10 volts, the 

alarm will sound, the red LED will light, 

and the converter will shut down. 

5.  BEFORE USING YOUR CONVERTER

Do not use the converter with a product 

that draws a higher wattage than the 

converter can provide, as this may cause 

damage to the converter and product.

When you turn on a device or a tool that 

runs on a motor, the device goes through 

two stages: 

1.  Start Up –

 Requiring an initial surge 

of power (commonly known as the 

“starting” or “peak” load).

2.  Continuous Operation –

 Power 

consumption drops (commonly known 

as the “continuous load”).

The wattage (WATTS) or amperes (AMPS) 

can normally be found stamped or printed 

on most devices and equipment, or in 

the user’s manual. Otherwise, contact 

the manufacturer to find out whether the 

device you want to use is compatible with 

a modified sine wave.

To calculate the wattage:

  

Wattage = AMPS x 120 (AC Voltage).

To calculate the starting load:

  

Starting Load = 2 x wattage. 

In general, the startup load of the device 

or power tool determines whether your 

converter has the capability to power it.

To calculate the continuous load: 

Continuous Load = AMPS x 120  

(AC Voltage).

IMPORTANT:

 Always run a test to 

establish whether the converter will 

operate a particular piece of equipment or 

device. In the event of a power overload, 

the converter is designed to automatically 

shut down. 

This safety feature prevents damaging 

the converter while testing devices and 

equipment within the wattage range of the 

converter.

If a device does not operate properly 

when first connected to the converter, turn 

the converter ON/OFF switch ON, OFF, 

and ON again in quick succession. If this 

procedure is not successful, it is likely that 

the converter does not have the required 

capacity to operate the device in question.

IMPORTANT:

 This converter uses a 

modified sine waveform (diagram A) 

which is not quite the same as power 

company electricity (diagram B). For the 

following devices, we strongly recommend 

that you use caution and check the 

device’s manual to make sure it is 

compatible with modified sine waveform.

Содержание BATTERY EXTENDER BE01257

Страница 1: ...CONSERVE ESTE MANUAL DEL USUARIO Y LEALO ANTES DE CADA USO En este manual le explica c mo utilizar el convertidor de manera segura y confiable Por favor lea y siga las siguientes instrucciones y prec...

Страница 2: ...e power converter to a 12V battery or power supply Do not attempt to connect the converter to any other power source including an AC power source Connecting to a 6V or 16V battery will cause damage to...

Страница 3: ...t runs on a motor the device goes through two stages 1 Start Up Requiring an initial surge of power commonly known as the starting or peak load 2 Continuous Operation Power consumption drops commonly...

Страница 4: ...1 Turn off and disconnect the converter 2 Locate the chassis ground screw on the back of the converter 3 Remove the outer hex nut and loosen the second hex nut 4 Attach the grounding wire s ring conne...

Страница 5: ...ve output cables to opposite ends of the bank Do not allow the output cables to touch one another 4 Test the voltages at the output cables to make sure that the battery bank is correctly wired 5 If th...

Страница 6: ...the USB port 2 Turn the USB device on 3 Reverse these steps when finished using the USB port WARNING The converter draws power even when the switch is OFF To avoid battery drain disconnect the conver...

Страница 7: ...oes not require opening the unit as there are no user serviceable parts All servicing should be performed by qualified service personnel 13 5 Store inside in a cool dry place out of the reach of child...

Страница 8: ...150 W Internal fuse 40A x 3 AC receptacles Two NEMA 5 15 USA USB port One 2A Battery cables One black one red Ground wire One green 16 REPLACEMENT PARTS Battery cable black 3899003407Z Battery cable r...

Страница 9: ...epaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied or...

Страница 10: ...cual puede llevar a una lesi n seria o la muerte 1 12 No coloque el convertidor sobre o cerca de ventilas de calefacci n radiadores u otras fuertes de calor o materiales inflamables 1 13 No coloque el...

Страница 11: ...Negativa del cable de la bater a Negra Termina la tierra y cable de tierra Conecta a tierra el convertidor para reducir la descarga el ctrica Protecci n t rmica Cuando el resistor t rmico supera los 8...

Страница 12: ...ecalentamiento Seno modificada de forma de onda producido por el convertidor Diagrama A Diagrama B Sinusoidal pura forma de onda t pico de la casa de la toma de CA IMPORTANTE Si usted esta usando el c...

Страница 13: ...dor l neas de combustible o cuerpos met licos Conecte a una pieza met lica de calibre grueso del marco o del bloque motor 4 Para desconectar el convertidor quite primero el terminal negativo y luego e...

Страница 14: ...tor del convertidor a la posici n de ON encendido I 3 La luz del indicador LED debe brillar VERDE verificando que el convertidor est recibiendo energ a 4 Cambie el interruptor de balanc n del converti...

Страница 15: ...positivo siendo operado con el convertidor Cuando sea posible recargar las bater as cuando no son m s del 50 de descargado Esto le da a las bater as de un ciclo de vida mucho m s larga que la recarga...

Страница 16: ...os componentes el ctricos internos 14 LOCALIZACI N Y SOLUCI N DE PROBLEMAS PROBLEMA CAUSA POSIBLE SOLUCI N Tensi n de salida baja o nula Mal contacto en las terminales El uso del tipo incorrecto de vo...

Страница 17: ...150 W Fusible interno 40 A x 3 Tomas de corriente CA Dos NEMA 5 15 USA Puerto USB Uno 2 A Cables de la bater a Uno negro uno rojo Cable de tierra Uno verde 16 PIEZAS DE REPUESTO Cable de bater a negr...

Страница 18: ...nos sean el Fabricante o si esta unidad es revendida a trav s de un vendedor minorista no autorizado El Fabricante no realiza ninguna otra garant a incluidas a t tulo enunciativo las garant as expresa...

Страница 19: ...e Purchased____________________ Date of Purchase__________ Store Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For...

Отзывы: