background image

It is a mix of technology and easy use.

The design, inspection and manufacturing of your Schulz tank is based on ASME Section VIII, Div. 1 - Code
and according to NR-13 MTb of Brazil.

You have purchased another product with Schulz quality.

A company Schulz S.A., with a quality system certified by

and environmental management system

ISO

9001

ISO

14001

This Instruction Manual provides important installation, use,
maintenance and safety instructions and must be at hand
whenever needed. Before operating the equipment, or
during maintenance, read this manual and make sure you
understand all of its instructions in order to avoid personal
injuries or damage to your compressor.

When using electric product, basic safety
precautions should always be followed to
reduce risk of fire, electric shock and
personal injuries.

IMPORTANT

WARNING

!

!

English

INSTRUCTION MANUAL

DIRECT DRIVE

AIR COMPRESSOR

MEDICAL ODONTOLOGICAL

OIL FREE MODELS

1) INTRODUCTION

1) INTRODUCTION

WE RECOMMEND READING THIS MANUAL PRIOR TO USING THIS PRODUCT.

It will help you to optimize product performance, guarantee safe use, and guide you in preventive maintenance.
Black numbers in the text, show the Main Parts and Their Functions, Chapter 6.

If there is any problem that cannot be solved by the information provided in this manual, please contact the
nearest Schulz Authorized Technical/Distributor.

In order to extend the useful life of this reciprocating piston compressor, the use of original parts Schulz are highly
recommended.

It is the responsibility of the user to install, inspect, maintain, operate and provide specific documentation for the
compressor and air/oil pressure vessel as required by applicable federal, state and local codes.

The pressure vessel quality certificate must be presented to authorities, in case of inspection. Keep it in a safe
place along with the instruction manual.

Schulz air compressors must only be used for air compression and up to the maximum compression indicated in
their Identification Tag/Information Sticker.

3) USES

3) USES

2) COMPRESSOR INSPECTION

2) COMPRESSOR INSPECTION

- Inspect for signs of obvious freight damage. Report any damage to the delivering freight carrier immediately.

- Be sure that all damaged parts are replaced and any mechanical problems are corrected prior to the operation of
the air compressor.

- The compressor serial number is located on the pump. Please write the serial number in the space provided in
the end this manual for future reference.

4) TECHNICAL DATA

4) TECHNICAL DATA

SHEET 03/04

025.0281-0

05/2009

rev. 09

CSV 15/220

CSV 15/250

CSV 20/220

CSV 20/250

MS 3/30

MSV 6/30

MSV 6/50

CSA 6,5/30

MSV 12/175

MSV 18/250

20.8 / 530

44.5 / 1,130

23.6 / 600

31.8

/

810

CABINET (OPTIONAL)

Weight = 66.2 lbs (30 kg)

MS 3/30
MSV 6/30

B

C

A

C

B

NOTE:

1- The tank filling up time varies from ± 10%, according to installation.
2 - MUNSELL 10Y 8.5/2.
3 - Electric motor available for working in 115 or 230V (MS 3 and MSV 6).
4 - Tank with internal painting (in powder) anticorrosive.
5 - Technical data of tank see the pressure vessel quality certificate.
6 - The cabinet reduce compressor noise level to less than 61 dB(A) and varies ± 3 dB(A) for models MS 3/30 and

MSV 6/30. Other models MS 3/30 (77), MSV 6/30(78), MSV 6/50 (78), MSV 12/175 (84), CSV 15/220 (82), CSV
15/250 (82), MSV 18/250 (82), CSV 20/220 (84,4) and CSV 20/250 (84,4) without cabinet.

7 - 25,4mm = 1” (inch).

MSV 12/175
MSV 18/250

CSV 15/220
CSV 20/220

CSV 15/250
CSV 20/250

D

B

E

A

4 x Ø F

C

C

B

A

D

E

1

1.8/300

4 x

F

ø

Tank with 4 x ø 5/8”/16mm
equidistant holes (90 )
in a radius of 9.8/250mm

o

18.3/467

A

TABLE 1 - TECHNICAL DATA

MODEL

MS 3/30

MSV 6/30

MSV 6/50

CSA 6,5/30

MSV 12/175

MSV 18/250

CSV 15/220

CSV 15/250

CSV 20/220

CSV 20/250

DISPLACEMENT

MÁX.

PRESSURE

TANK

rpm

l/min

l/min

bar

Volume

gal ()

l

Filling up time

cfm

cfm

50Hz

50Hz

50Hz

60Hz

60Hz

60Hz

3.0

6.0

6.0

6.5

12.0

18.0

15.0

15.0

20.0

20.0

2.5

5.0

5.0

5.2

10.0

15.0

15.0

15.0

20.0

20.0

84

170

170

185

340

509

425

425

566

566

70

141

141

148

282

425

425

425

566

566

120

8/29

8/29

12/45,7

8/29

47/178

69/261

59/224

69/261

59/224

69/261

7'10''

3'50'’

11'50'’

9’55”

5'25'’

4’40”

9’30”

9’40”

4’

4’50”

6’10”

3’10”

4 35

10'15'’

8’15”

3’30”

9’30”

9’40”

4’

4’50”

1,420

1,445

1,445

1,440

1,445

1,445

620

620

1,050

1,050

1,720

1,730

1,730

1,670

1,730

1,730

620

620

1,050

1,050

psig

8,3

500

500

400

500

520

550

500

540

500

540

0.37

0.75

0.75

1.1

2x0.75

3x0.75

2.2

2.2

3.7

3.7

34

42

54

22

109

160

167

169

168

170

61/77

61/78

78

70

84

82

85

85

89

89

460

460

400

460

1,080

1,550

820

1,700

820

1,700

645

630

620

630

880

850

1,850

1,032

1,850

1,032

-

-

-

-

550

800

-

800

-

800

-

-

-

-

460

460

-

460

-

460

-

-

-

-

18

16

16

16

16

16

A

DIMENSIONS (mm)

PAINTING

(see note 2)

WEIGHT

(kg)

NOISE

dB )

(see note 6)

(A

B

C

D

E

F

PUMP

(WHITE)

TANK

(WHITE

IN POWDER)

110/220

Single-phase

110/220 Single-phase

(220/380/440 Three-phase)

220/380/440

Three-phase

220 Single-phase

110 or 220 Single-phase

VOLTAGE

(V)

poles

4

2

1/2

1

1

1.5

2x1

3x1

3

3

5

5

hp

ELECTRIC MOTOR

kW

(110/220

)

Single-phase

5) SAFETY INSTRUCTIONS

5) SAFETY INSTRUCTIONS

1.

2.

4.

5.

-

-

-

-

-

-

-

3.

This equipment:

has hot and electric parts and moving pieces;

the models MS 3, MSV 6 and CSA 6,5 are supplied with plug 2P + GR (Ground). For your safety, do

not cut the “GR” pin or use an adapter “2P”;

- make sure the compressor is correctly grounded;

may start or stop automatically, when connected to the electric supply, depending on the tank's

pressure or on the functions of the electric protective elements;

may cause mechanical or electric interference in other equipment which may be placed nearby;

should not operate in places where access to non-authorized people, children or animals is

permitted;

requires an authorized person to supervise its use and maintenance, and equipment protection must be
worn;

must be installed and operated in a well ventilated area and with protection against humidity or water.

Never exceed the maximum pressure indicated in the compressor's identification tag

.

Never change the adjustment of the safety valve or pressure switch, since they have already been regulated
factory. If an adjustment of the pressure switch is required, look for the nearest Schulz Authorized Technical/
Distributor.

Never perform welding jobs or repairs in the tank because they may affect its resistance or disguise

more serious problems. If there is any leakage, crack or corrosion, immediately stop the equipment
use and look for the nearest Schulz Authorized Technical/Distributor.

Never run the pressure vessel above the maximum pressure indicated in its identification tag

.

13

14

When improperly used, an air compressor can cause physical and material damage.
Please, follow the recommendations below to avoid them :

!

CSA 6,5/30

C

A x B

Содержание MS 3/30

Страница 1: ...esi n 6 La cabina atenua el nivel de ruido del compresor MS 3 30 y MSV 6 30 para 61dB A Medido a 1m de dist ncia y variaci n de 3dB A Para los modelos MS 3 30 MSV 6 30 MSV 6 50 MSV 12 175 MSV 18 250 C...

Страница 2: ...arter conecta y desconecta utilizada para el producto MSV 18 250 suministrada para el mercado Argentino no indicada en el foto y modelos CSV 15 y CSV 20 aisla vibraci n producida por el equipo del pis...

Страница 3: ...rifique si el sentido de rotaci n correcto es anti horario visto del ventilador volante Deje el compresor trabajar por unos 10 diez minutos a fin de permitir la lubricaci n homog nea de las partes m v...

Страница 4: ...ue del compresor a trav s de procesos que busquen garantizar la protecci n al medio ambiente y la sana calidad de vida de la poblaci n en conformidad con los requisitos reglamentares de la legislaci n...

Страница 5: ...30 78 MSV 6 50 78 MSV 12 175 84 CSV 15 220 82 CSV 15 250 82 MSV 18 250 82 CSV 20 220 84 4 and CSV 20 250 84 4 without cabinet 7 25 4mm 1 inch MSV 12 175 MSV 18 250 CSV 15 220 CSV 20 220 CSV 15 250 CS...

Страница 6: ...13 Identification Tag Information 14 Air compressor s identification Tag 15 Cabinet MS 3 MSV 6 CSA 6 5 MSV 12 and MSV 18 makes the compressor unit run with to help of the pulley and belt CSV 15 and CS...

Страница 7: ...ough pressure switch when the pressure gauge shows pressure around 80 psig 5 5 bar Check the air tank s filling up time according to Table 1 Close the pressure regulator and unplug the equipment Verif...

Страница 8: ...regular use and that are affected by the installation and the way the product is used are excluded from this warranty such as air filter element gaskets valves rings cylinders pistons connecting rods...

Отзывы: