It is a mix of technology and easy use.
The design, inspection and manufacturing of your Schulz tank is based on ASME Section VIII, Div. 1 - Code
and according to NR-13 MTb of Brazil.
You have purchased another product with Schulz quality.
A company Schulz S.A., with a quality system certified by
and environmental management system
ISO
9001
ISO
14001
This Instruction Manual provides important installation, use,
maintenance and safety instructions and must be at hand
whenever needed. Before operating the equipment, or
during maintenance, read this manual and make sure you
understand all of its instructions in order to avoid personal
injuries or damage to your compressor.
When using electric product, basic safety
precautions should always be followed to
reduce risk of fire, electric shock and
personal injuries.
IMPORTANT
WARNING
!
!
English
INSTRUCTION MANUAL
DIRECT DRIVE
AIR COMPRESSOR
MEDICAL ODONTOLOGICAL
OIL FREE MODELS
1) INTRODUCTION
1) INTRODUCTION
WE RECOMMEND READING THIS MANUAL PRIOR TO USING THIS PRODUCT.
It will help you to optimize product performance, guarantee safe use, and guide you in preventive maintenance.
Black numbers in the text, show the Main Parts and Their Functions, Chapter 6.
If there is any problem that cannot be solved by the information provided in this manual, please contact the
nearest Schulz Authorized Technical/Distributor.
In order to extend the useful life of this reciprocating piston compressor, the use of original parts Schulz are highly
recommended.
It is the responsibility of the user to install, inspect, maintain, operate and provide specific documentation for the
compressor and air/oil pressure vessel as required by applicable federal, state and local codes.
The pressure vessel quality certificate must be presented to authorities, in case of inspection. Keep it in a safe
place along with the instruction manual.
Schulz air compressors must only be used for air compression and up to the maximum compression indicated in
their Identification Tag/Information Sticker.
3) USES
3) USES
2) COMPRESSOR INSPECTION
2) COMPRESSOR INSPECTION
- Inspect for signs of obvious freight damage. Report any damage to the delivering freight carrier immediately.
- Be sure that all damaged parts are replaced and any mechanical problems are corrected prior to the operation of
the air compressor.
- The compressor serial number is located on the pump. Please write the serial number in the space provided in
the end this manual for future reference.
4) TECHNICAL DATA
4) TECHNICAL DATA
SHEET 03/04
025.0281-0
05/2009
rev. 09
CSV 15/220
CSV 15/250
CSV 20/220
CSV 20/250
MS 3/30
MSV 6/30
MSV 6/50
CSA 6,5/30
MSV 12/175
MSV 18/250
20.8 / 530
44.5 / 1,130
23.6 / 600
31.8
/
810
CABINET (OPTIONAL)
Weight = 66.2 lbs (30 kg)
MS 3/30
MSV 6/30
B
C
A
C
B
NOTE:
1- The tank filling up time varies from ± 10%, according to installation.
2 - MUNSELL 10Y 8.5/2.
3 - Electric motor available for working in 115 or 230V (MS 3 and MSV 6).
4 - Tank with internal painting (in powder) anticorrosive.
5 - Technical data of tank see the pressure vessel quality certificate.
6 - The cabinet reduce compressor noise level to less than 61 dB(A) and varies ± 3 dB(A) for models MS 3/30 and
MSV 6/30. Other models MS 3/30 (77), MSV 6/30(78), MSV 6/50 (78), MSV 12/175 (84), CSV 15/220 (82), CSV
15/250 (82), MSV 18/250 (82), CSV 20/220 (84,4) and CSV 20/250 (84,4) without cabinet.
7 - 25,4mm = 1” (inch).
MSV 12/175
MSV 18/250
CSV 15/220
CSV 20/220
CSV 15/250
CSV 20/250
D
B
E
A
4 x Ø F
C
C
B
A
D
E
1
1.8/300
4 x
F
ø
Tank with 4 x ø 5/8”/16mm
equidistant holes (90 )
in a radius of 9.8/250mm
o
18.3/467
A
TABLE 1 - TECHNICAL DATA
MODEL
MS 3/30
MSV 6/30
MSV 6/50
CSA 6,5/30
MSV 12/175
MSV 18/250
CSV 15/220
CSV 15/250
CSV 20/220
CSV 20/250
DISPLACEMENT
MÁX.
PRESSURE
TANK
rpm
l/min
l/min
bar
Volume
gal ()
l
Filling up time
cfm
cfm
50Hz
50Hz
50Hz
60Hz
60Hz
60Hz
3.0
6.0
6.0
6.5
12.0
18.0
15.0
15.0
20.0
20.0
2.5
5.0
5.0
5.2
10.0
15.0
15.0
15.0
20.0
20.0
84
170
170
185
340
509
425
425
566
566
70
141
141
148
282
425
425
425
566
566
120
8/29
8/29
12/45,7
8/29
47/178
69/261
59/224
69/261
59/224
69/261
7'10''
3'50'’
11'50'’
9’55”
5'25'’
4’40”
9’30”
9’40”
4’
4’50”
6’10”
3’10”
4 35
10'15'’
8’15”
’
”
3’30”
9’30”
9’40”
4’
4’50”
1,420
1,445
1,445
1,440
1,445
1,445
620
620
1,050
1,050
1,720
1,730
1,730
1,670
1,730
1,730
620
620
1,050
1,050
psig
8,3
500
500
400
500
520
550
500
540
500
540
0.37
0.75
0.75
1.1
2x0.75
3x0.75
2.2
2.2
3.7
3.7
34
42
54
22
109
160
167
169
168
170
61/77
61/78
78
70
84
82
85
85
89
89
460
460
400
460
1,080
1,550
820
1,700
820
1,700
645
630
620
630
880
850
1,850
1,032
1,850
1,032
-
-
-
-
550
800
-
800
-
800
-
-
-
-
460
460
-
460
-
460
-
-
-
-
18
16
16
16
16
16
A
DIMENSIONS (mm)
PAINTING
(see note 2)
WEIGHT
(kg)
NOISE
dB )
(see note 6)
(A
B
C
D
E
F
PUMP
(WHITE)
TANK
(WHITE
IN POWDER)
110/220
Single-phase
110/220 Single-phase
(220/380/440 Three-phase)
220/380/440
Three-phase
220 Single-phase
110 or 220 Single-phase
VOLTAGE
(V)
poles
4
2
1/2
1
1
1.5
2x1
3x1
3
3
5
5
hp
ELECTRIC MOTOR
kW
(110/220
)
Single-phase
5) SAFETY INSTRUCTIONS
5) SAFETY INSTRUCTIONS
1.
2.
4.
5.
-
-
-
-
-
-
-
3.
This equipment:
has hot and electric parts and moving pieces;
the models MS 3, MSV 6 and CSA 6,5 are supplied with plug 2P + GR (Ground). For your safety, do
not cut the “GR” pin or use an adapter “2P”;
- make sure the compressor is correctly grounded;
may start or stop automatically, when connected to the electric supply, depending on the tank's
pressure or on the functions of the electric protective elements;
may cause mechanical or electric interference in other equipment which may be placed nearby;
should not operate in places where access to non-authorized people, children or animals is
permitted;
requires an authorized person to supervise its use and maintenance, and equipment protection must be
worn;
must be installed and operated in a well ventilated area and with protection against humidity or water.
Never exceed the maximum pressure indicated in the compressor's identification tag
.
Never change the adjustment of the safety valve or pressure switch, since they have already been regulated
factory. If an adjustment of the pressure switch is required, look for the nearest Schulz Authorized Technical/
Distributor.
Never perform welding jobs or repairs in the tank because they may affect its resistance or disguise
more serious problems. If there is any leakage, crack or corrosion, immediately stop the equipment
use and look for the nearest Schulz Authorized Technical/Distributor.
Never run the pressure vessel above the maximum pressure indicated in its identification tag
.
13
14
When improperly used, an air compressor can cause physical and material damage.
Please, follow the recommendations below to avoid them :
!
CSA 6,5/30
C
A x B