GFCI verification procedure:
1- Increase the temperature set point until the heating power
bars are displayed (displayed beside the floor temperature).
2- Press down the Test button.
3- The following two cases can occur:
a) Successful test: The red indicator of the thermostat lights
up. In this case, press down the Test button to reinitialize
the Ground-Fault Circuit Interrupter, the red indicator
turns off.
b) Failed test: The red indicator does not light up and
the entire display blinks for 5 seconds. In this case,
disconnect the heating system at the electrical panel.
Security mode
This mode imposes a maximum temperature set point which
is impossible to exceed regardless of the mode in progress.
However, it is still possible to lower the set point at your
discretion. Please note that when the Security mode is
activated, it is impossible to switch from the
mode to the
mode, and conversely.
Procedures to activate Security mode:
1. To activate the Security mode, the thermostat should be
in Day mode. Exit any adjustment mode to manually adjust
the set point at the desired maximum value.
2. Simultaneously press down the + and - buttons for 10
seconds (note that after 3 seconds, the icon starts to
blink and the software version and date are displayed.
Continue to press down these buttons).
3. After 10 seconds, the icon is displayed indicating that
the Security mode is activated. Then, release the buttons.
Procedures to deactivate Security mode:
1. To deactivate the Security mode, cut off the power supply
of the thermostat at the electrical panel and wait at least
20 seconds.
14