2.   Operating Advice 

 

 

Because of the chemical resistance use only a damp cloth for cleaning the light fitting. If necessary 
with a mild and solvent-free cleaning agent. 

 

 

Against penetration of humidity into the light fitting a special explosion-proof breathing gland is often 
quite effective. It is allowed to use a breathing gland which is released by the Adolf Schuch GmbH 
only. If using a breathing gland please observe the general informations of it's operation 
instructions. 

 

 

Any application of the light fitting that is incorrect or even forbidden will lead to the fact that the 
manufacturer's warranty is lost. 

 

 

Opening the LED compartment is allowed for repair work only. 

 

 

LED are sensitive electronic components. Please ensure that the LED are protected against 
mechanical and electrostatic attacks whenever the light fitting is open. For this reason the LED 
must not be touched either. 

 

 

Due to harmful gases and other corrosive substances (e.g. ammoniac- sulphur-, or chlorine 
compounds) it may come to damages of the LEDs. Depending on the substance, the concentration, 
the temperature and the dwell time, damages up to total black-out are possible. This may occur 
also to fittings with high degree of protection. The suitability of the light fitting for the respective 
application can only be checked by running a test at site. 

 

 

Due to a high inrush current when switching on the light fitting, the number of light fittings which can 
be connected to a single fused circuit is limited (Possible number of light fittings per circuit breaker 
see Chapter 3, Technical Data). 

 

 

All DALI dimmable light fi

ttings have two additional terminals marked „DA“. Lines to the control 

terminals must be mains voltage proof. 

 

 

LED modules are built up of a series connection, which itself is built up of parallel connections of 
single LEDs. Failures of LEDs do not necessarily lead to a change in the power consumption, 
which is recognized by the emergency light unit. 

 

2.1   Use at low temperatures 

 

The safety of the light fitting is warranted between -30°C up to +60°C. 
At temperatures below 0 °C, it must be taken into account that the emergency battery will take longer 
to charge and the operational life of the emergency lighting mode will be reduced. Testing the duration 
of the battery life in lower ambient temperatures can therefore lead to a misleading result. 
The battery life test should be repeated manually at a more appropriate time (please refer to the 
section about operational life testing in Chapter 2.2).  

 

2.2   Automatic test of the emergency light unit 

 

The functionality of the light fitting and the operational life in emergency lighting mode is tested 
automatically by the emergency light unit at specified intervals. A blinking green light is emitted by the 
signal LED while the test is being carried out. 

 

Functionality test 
Functionality tests are carried out at 7 day intervals and last one minute. 
The first test of functionality is carried out one hour after the light fitting has been setup. Before this can 
happen, it is necessary to separate the emergency light unit built into the light fitting from the mains 
power supply before switching on the power, and the emergency battery must have been charged 
continuously for one hour. 

 

Operational life test 
During the operational life test, the emergency light unit checks whether the capacity of the emergency 
battery is sufficient for the indicated nominal operating time should the emergency light being required. 

 

For the operational life test to be carried out, the emergency battery must be fully charged and 
connected. For special versions with the option to deactivate the emergency light function, the remote 

Содержание e864 12L Series

Страница 1: ...ends on the observance of all safety standards Exact knowledge about all applicable regulations and standards is mandatory for installation maintenance and repair of explosion proof equipment especial...

Страница 2: ...ubject to any kind of vibrations it is highly recommended to consult the Adolf Schuch GmbH before starting the installation Every structural modification will cause dangerous situations and consequent...

Страница 3: ...up of a series connection which itself is built up of parallel connections of single LEDs Failures of LEDs do not necessarily lead to a change in the power consumption which is recognized by the emerg...

Страница 4: ...itions after a correctly performed switching sequence at L1 terminal an operational life test is immediately initiated If the switching sequence is correctly carried out on L1 terminal an operational...

Страница 5: ...connection between the emergency light unit and the battery is re established 2 4 LED Signals The two colored LED red green which is integrated in the reflector of the light fitting does show the work...

Страница 6: ...the light fitting 3 Technical Data Series e864 12L Capacity of emergency battery Nominal operating time in case of emergency Index of luminous flux Explosion proof LED Emergency Light Fitting for oper...

Страница 7: ...ion position in any direction except upwards light output Rated luminous flux ca 16 with e864 12L42 ca 12 with e864 12L60 Spare battery Typ 8020 6 V 1 6 Ah NiCd 1 hour emergency light time standard ve...

Страница 8: ...fitting in an explosive dust atmosphere is depending on the properties of the surrounding dust Please ensure that there will be an adequate difference between the maximum surface temperature of the f...

Страница 9: ...es which are not used must be closed with the enclosed closure plug Torque see Chapter 3 Technical Data An inlaid dust protective disc if existing must be removed before The conductors must not be dam...

Страница 10: ...elivery state there is no electrical connection between the emergency battery and the emergency light unit If no power supply is present even if the light fitting is connected to the emergency battery...

Страница 11: ...k and ensure that the light fitting has been installed according to the regulations and in the allowed operating position the explosion proof cable glands resp explosion proof locking screws are secur...

Страница 12: ...s in 3 phase circuits and with a common neutral conductor N Light fittings with emergency light unit OK fault If the common neutral conductor is interrupted and voltage is present then light fittings...

Страница 13: ...have got thermal insulation characteristic features It is necessary to clean the fitting from dust regularly In case the dust layer may be higher than 5 mm it must be ensured that the surface tempera...

Страница 14: ...ctor with mounted LED modules has been described in the separate instructions which can be found attached to the spare parts to be supplied 6 5 Environmental advice This device has got an accumulator...

Страница 15: ...L 014124 04 15...

Страница 16: ...16 L 01412 4 04 The test certificates are ready to be loaded down from our homepage www schuch de or we shall send it on request Misprints modifications and errors are excepted...

Отзывы: