background image

Page9

Page10

Instruction of Using Our Products

Instruction of Using Our Products

. CONNECTION DIAGRAM

. SYSTEM INSTALLATION SKETCH

 POWER INPUT

(AC220V/16A)

SPEAKER

10W

CONTROL 

BOX

AC 

12V/10W

O

3

COMPUTER CONTROL BOX

ANT

LIGHT

12V/20W

WATER PUMP

1HP

AIR PUMP

1HP

HEAT

220V/1.5kW

MASSAGE BATHTUB

. EXTERIOR DESCRIPTION: (CONTROL PANEL)

.  DESCRIPTION OF FUNCTION INDICATE LIGHT:

1. Heater Indicator: Heater starts to work if it is on. (Remarks:during the operation, the 
    indicator turns off automatically if there is no sufficient water; when the water level 
    reaches the standard, the indicator is on and the heater starts to work again)
2. Water Indicator: If it is on, the massage function is effective; if it flashes, it shows that 
    there is no sufficient water so the massage function is of no effect.
3. Bubble Bath Indicator: if it is on, the bubble bath function is effective, if it is off, this 
    function is off.
4. O

Indicator: if it is on, the underwater light is on, if it flashes, the ozonation function is 

    effective. (Remarks: when the underwater light is on and ozonation function is effective, 
    this indicator will flash 5 times and pauses once then continue to flash!)

Power 

Switch

Heat 

Switch

MEMORY/TAKE 

Programs Switch

Water Light 

Switch

CD/RADIO 

Switch

Function 

Indicate Light

Water Pump 

Switch

LED Display Screen

 Volume Increasing
 Channel Switch
 Temperature Increasing

 Volume Decreasing
 Channel Switch
 Temperature Decreasing

Air Pump 

Switch

Channel Selecting Switch

Ozonizer 

Switch

POWER  INPUT

AC220V/16A

E

E

L

N

LIG

SPK

AC220V

E

N

L

ANT

C

D

 IN

P

U

T

WATER PUMP

AC220V/1HP

AC220V0.5A

M

M

E

E

E

E

N

N

L

L

M

M

E

E

AIR BUBBLE PUMP

AC220V/1HP

 WATER

CONTROL

LIGHT

AC12V/20W

SPEAKER

8

/10W

N

N

L

L

N

N

L

L

FUSE

3A

E

N

L

O

3

OZONIZER

AC12V/20W

HEATER

220V/1.5kW

1. LED-display screen: the display shows different when pressing (

  )key/(

  )key 

    continuously.  The display shows alternately (Measure Temperature/Setting 
    Temperature/FM Radio Frequency) when heating and radio are both working.

. NOTES FOR DIGITAL DISPLAY:

2. When the RADIO:

FM

MHz

FM RADIO FREQUENCY

AC7.5V

AC12V

Содержание HAMBURG

Страница 1: ...it can be wiped off with warm citric acid or vinegar by a soft cloth 4 Don t clean the tub and with hard or coarse material to avoid any scratches 5 Don t clean the tub and with gasoline to avoid any damages 6 It is not recommended to leave water in the tub for a long time or use this tub for washing purpose Pls drain off the water after the bath and dissconnect the power supply 7 There should be ...

Страница 2: ... pressure sugar diabetes should not take a steam shower or bath when feeling sick The kid is suggested to be accompanied by an adult when taking a bath 2 Don t take a bath alone after drinking wine with alcohol or excess sports 3 The water temeperature should be below 45 during shower and the recommended temperature is 30 38 4 Don t take a bath for a long time Recommended time 15 21 5 All the info...

Страница 3: ... spanner to screw it 5 Distinguish the water pipes of faucet 6 Use spanner to screw the tie in Installation Process Preparations 680mm 1630mm 1630mm 1 Control Panel 2 Inlet Waterfall 3 Switch Handle 4 Cold Water Handle 5 Hot Water Handle 6 Shower Head 7 Small Jets 8 Pillow 9 Volume Control Water Circulation Light Drainer Drainer Switch 11 12 13 14 10 15 Air Jets Big Water Jets 600mm 600mm 560mm Dr...

Страница 4: ...the bathtub then install downcomer 6 Use thread sealing tape to wrap around the drain hole 7 Make the thread sealing tape smooth 8 Fasten the drain tube 9 Put downcomer into the drain hole on the ground 11 Put plugs into the drain hole 10 Drain sewage of the tube then connect the cold and hot water pipe separately 12 Install pillow Installation Process Installation Process ...

Страница 5: ... automatically cut off the circuit if the current is too high 2 Volume control 3 Waste water free piping system Page7 Page8 Unique Point Installation Process Installation Process 13 Seal the barthtub edge by silicon glue as follows ...

Страница 6: ... the underwater light is on if it flashes the ozonation function is effective Remarks when the underwater light is on and ozonation function is effective this indicator will flash 5 times and pauses once then continue to flash Power Switch Heat Switch MEMORY TAKE Programs Switch Water Light Switch CD RADIO Switch Function Indicate Light Water Pump Switch LED Display Screen Volume Increasing Channe...

Страница 7: ...reset Temperature by factory 45 6 Temperature Setting 6 Temperature Setting VOL Please Press The Key TECHNICAL DATA 1 Voltage AC220V 10 50Hz AC110V 10 60Hz 2 Power 3500W 3 Dielectric Strength 1500V 1min 4 Lighting Load AC12V 20W 5 Music Power 15W 6 Frequency Range FM88 108MHz 7 S N Radio 45dB 8 AIR PUMP AC220V50Hz 1kW 9 HEAT POWER AC220V50Hz 1 5kW 10 AC12V 20W 11 WATER PUMP POWER 1kW Ozone OPERATI...

Страница 8: ...ose the desired volume by pressing VOL or VOL 3 External CD PRECAUTIONS 4 Key Description 1 It is the store function after pressing or after station selection and direct pressing of the key is selecting the channels that have been memorized 2 VOL and VOL Function it is for temperature adjustment when the radio and CD functions are ineffective while the radio or CD functions is effective it is for ...

Отзывы: