GB
25
Table 1
Liquid gas
Natural gas
Burner
Diameter
(mm)
Thermal
power
kW
(p.c.s.*)
power
kW
(p.c.s.*)
By-pass
1/100
(mm)
Nozzle
1/100
Flow*
g/h
power
kW
(p.c.s.*)
Nozzle
1/100
Flow*
l/h
1/100
Flow*
l/h
Red.
Nom.
(mm)
***
**
Nom.
(mm)
(mm)
(Large) (R)
100
0,70
3,00
39
86
218
214
3,00
116
286
143
286
Reduced Fast
(RR)
100
0,70
2,60
39
80
189
186
2,60
110
248
135
248
Ultra Fast (UR)
100
0,70
3,40
39
91
247
243
3,40
123
324
135
248
Semi Fast
(Medium) (S)
75
0,40
1,65
28
64
120
118
1,65
96
157
105
157
Auxiliary
(Small) (A)
55
0,40
1,00
28
50
74
71
1,00
79
95
80
95
Mini WOK (MW)
110
1,30
3,50
57
91
254
250
3,50
138
343
155
333
Mini
DUAL
MD
internal
40
0,20
0,60
23
37
44
43
0,70
66
67
76
86
MD
external
108
1,30
4,00
54
93
291
286
4,00
135
381
124
438
Supply pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
13
6,5
18
Burner and nozzle specifications
Fast
Thermal
Thermal
Nozzle
*
At 15°C and 1013,25 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m3
A
S
R
S
A
S
MW
S
A
A
UR
RR
S
S
MD
RR
S
S
TV 750 GH
MW
TV 640 GH
TV 751 GH
SCHG 751 GH
SCHG 640 GH
A
S
R
Ø 145
TV 631 E GH
A
R
TV 631 GH
TV 641 GH