Страница 1: ......

Страница 2: ......

Страница 3: ...SIBLE FOR WHATEVER INJURIES OR DAMAGES ARE CAUSED BY INCORRECT INSTALLATION OR BY UNSUITABLE WRONG OR ABSURD USE Dear customer We thank you and congratulate you on your choice This new carefully de signed product manufactured with the highest quality materials has been carefully tested to satisfy all your cooking demands We would therefore request you to read and follow these easy instructions whi...

Страница 4: ...bustible materials ENG 8 If another built in appliance e g dishwasher washer etc is to be installed under the gas hob keep a clearance of at least 15mm from the bottom of the gas hob If the installation instruction of the appliance underneath requires a different distance adopt the larger value 9 Allow 650mm clearance above gas hob Operation 1 In case of suspected gas leak open windows and shut of...

Страница 5: ... food and liquid once it cools down iii Turn off the burner immediately when abnormal noise is heard Restart burner and check whether the problem persists If yes stop using it and call Scholtès Customer Services Hotline for service iv Dry burner heads completely with dry cloth after washing Burner flame holes must be free from water lest combustion is affected v Do not put total weight exceeding 1...

Страница 6: ...imum position Turn the knob to adjust flame power according to cooking needs The minimum position is found at the end of the anti clockwise rotation direction The electric spark from ignition electrode ignites the burner After ignition keeping the knob fully pressed on the maximum position for approximately 5 seconds After releasing the knob make sure the flame persists Maintenance Allow the appli...

Страница 7: ...4 ENG ...

Страница 8: ...ecting a flexible stainless steel pipe to a threaded end The gas supply pipe connection of the hob is a threaded male end The flexible pipe must not be longer than 2000 mm when fully extended Once connection has been carried out make sure that the flexible metal pipe does not touch any moving parts and is not compressed N B Checking the tightness of the connection When the installation has been ca...

Страница 9: ...ssure 1 5 kPa Governor Outlet Pressure 1 0 kPa Gas Inlet Connection 1 2 B S P Male Height 116 71 Width 295 Depth 520 Dimensions mm from bottom to pan support mm from bottom to top plate mm mm Top plate thickness 8 mm Base tray height 63 mm Cut out Dimensions Width 270 Depth 494 mm mm Weight 5 5 kg 6 0 kg Power Supply 220 240V AC 50 Hz ENG ...

Страница 10: ...rner head is blocked by aluminum disc Remove aluminum disc Yellow flame Accumulated grease cooking spillage and dirt on burner head Wash burner head in warm water with detergent Dry it and place it back at correct position Unstable flame 1 Deformation of burner heads 2 Incorrect placement of burner head 1 Contact Scholtès Customer Services Hotline to replace the parts 2 Refit burner head into burn...