6.  Menu and further functions  

 
To access the menu, briefly press the (I) button [3] upwards. 
By pressing the (I) button upwards, you can scroll through the menu items. 
To select an entry, press the (I) button [3] downwards. 
 
You can select from the following: 
 

6.1.

 

Switch off

 

 
Switches the device off. 
 
To switch off the device, select the "switch off" entry and press the (I) button down. 
 

6.2. To measuring

 

 
Takes you back to measuring. 
 
To return to measuring, select the entry "to measuring" and press the 

(I)  button down. 

 

6.3. Show memory 

 
All stored measurement results with date and time are displayed here. 
 
To access the stored measurement results, select the "show memory" entry and press the 
(I) button down. 
 
To return to the measurement, press the (I) button downwards. 
 
To save measured values, press the reset / save button upwards after the measurement. 
 

6.4. Clear memory 

 
Here you can clear the stored measurement results. 
 
To delete all measured values, select the "clear memory" entry and press the (I) button 
down. 
In the following screen, select the entry "yes" and press the (I) button down. 
 
To delete only individual measured values, select the entry "show memory" and press the 
(I) button downwards.  
By pressing the reset/save button downwards, the top value is deleted. 
 
 
 
 
 
 
 
 
 
 
 

Содержание 810523

Страница 1: ...1 Part No 810523 Operating manual FLOCK Checker...

Страница 2: ...operating instructions 4 3 Intended use 4 4 Structure and overview 5 4 1 Structure of the FLOCK Checker 5 5 Functional description 6 5 1 Commissioning 6 5 2 Display 7 5 3 Performing measurements 8 5...

Страница 3: ...turer of flock fibers offers different fibers with different preparations Accord ingly these also have different conductivity Please refer to the respective data card of your fibers for the exact date...

Страница 4: ...St IdNr DE 146 481 986 General Manager Olav Schnier 2 Guide to these operating instructions These operating instructions must be read understood and observed in all points by all persons who are respo...

Страница 5: ...BAL EN 220609 Status 06 09 2022 Seite 5 von 12 4 Structure and overview 4 1 Structure of the FLOCK Checker 1 Electrode 2 Display 3 I Button 4 Reset Save Button 5 Cover charging socket 6 POAG Plug for...

Страница 6: ...t Remove the protective cap Press the I button 3 upwards and hold for approx 2 seconds The unit starts up and performs a self test As soon as the value 0 is shown in the display 2 the FLOCK Checker is...

Страница 7: ...rating manual 810523 BAL EN 220609 Status 06 09 2022 Seite 7 von 12 5 2 Display 1 Battery indication and time 2 Current measured value 3 Maximum measured value 4 Number of stored measured values 1 2 3...

Страница 8: ...eset Save button 4 down once To save the value press the Reset Save button 4 upwards This also sets the value in the display to 0 The value Max is also shown in the display This is the maximum value t...

Страница 9: ...he I button down 6 3 Show memory All stored measurement results with date and time are displayed here To access the stored measurement results select the show memory entry and press the I button down...

Страница 10: ...tton down Then select the Yes entry and confirm by pressing the I button downwards The device vibrates briefly to confirm 6 5 3 Date Here you can set the date and time To do this select the Date entry...

Страница 11: ...han 125 standard scale division Nrm Simply delete it again by pressing the I button downwards You can then carry out a new measurement 8 Scope of delivery FLOCK Checker Attachment electrode with prote...

Страница 12: ...en Product Measuring device Type Conductivity meter SCHNIER Part No FLOCK Checker Part No 810523 Handelsbezeichnung FLOCK Checker Function Measuring instrument for determining the conductivity of floc...

Отзывы: