SCHNIER 810523 Скачать руководство пользователя страница 4

 

Operating manual 810523-BAL-EN-220609 

 Status 06.09.2022 

Seite 4 von 12 

 

1.5.

 

Warranty

 

 

The warranty is 24 months after delivery. 
Any kind of warranty expires if the device has been opened, modified, parts have been 
replaced with non-original parts or these operating instructions have not been observed. 

 

1.6.

 

Manufacturer

 

 

SCHNIER Elektrostatik GmbH 

Bayernstr. 13 
72768 Reutlingen 
Deutschland 

Phone:  

+49 (0) 71 21 / 90 973 - 60 

Fax:    

+49 (0) 71 21 / 90 973 - 99 

 
www.schnier.de 
www.schnier-flock.de 
[email protected] 
 
Headoffice:    

Reutlingen HBR 354 531 

USt.-IdNr.:  

 

DE 146 481 986  

General Manager:  

Olav Schnier 

 

2.  Guide to these operating instructions 

 
These operating instructions must be read, understood and observed in all points by all 
persons who are responsible for the equipment. Only with knowledge of these operating 
instructions errors can be avoided and safe and trouble-free operation be ensured. 
SCHNIER Elektrostatik GmbH does not accept any liability for damage resulting from non-
observance of these operating instructions! 
 

3.  Intended use 

 
This instrument is intended exclusively for use as a conductivity meter of flock fibers. 
 

 

 
Any commissioning outside this provision is prohibited. 
 

 
Damages / modifications: 
 

 

No structural modifications of any kind may be made to this device. 

 
 
 
 
 
 

Содержание 810523

Страница 1: ...1 Part No 810523 Operating manual FLOCK Checker...

Страница 2: ...operating instructions 4 3 Intended use 4 4 Structure and overview 5 4 1 Structure of the FLOCK Checker 5 5 Functional description 6 5 1 Commissioning 6 5 2 Display 7 5 3 Performing measurements 8 5...

Страница 3: ...turer of flock fibers offers different fibers with different preparations Accord ingly these also have different conductivity Please refer to the respective data card of your fibers for the exact date...

Страница 4: ...St IdNr DE 146 481 986 General Manager Olav Schnier 2 Guide to these operating instructions These operating instructions must be read understood and observed in all points by all persons who are respo...

Страница 5: ...BAL EN 220609 Status 06 09 2022 Seite 5 von 12 4 Structure and overview 4 1 Structure of the FLOCK Checker 1 Electrode 2 Display 3 I Button 4 Reset Save Button 5 Cover charging socket 6 POAG Plug for...

Страница 6: ...t Remove the protective cap Press the I button 3 upwards and hold for approx 2 seconds The unit starts up and performs a self test As soon as the value 0 is shown in the display 2 the FLOCK Checker is...

Страница 7: ...rating manual 810523 BAL EN 220609 Status 06 09 2022 Seite 7 von 12 5 2 Display 1 Battery indication and time 2 Current measured value 3 Maximum measured value 4 Number of stored measured values 1 2 3...

Страница 8: ...eset Save button 4 down once To save the value press the Reset Save button 4 upwards This also sets the value in the display to 0 The value Max is also shown in the display This is the maximum value t...

Страница 9: ...he I button down 6 3 Show memory All stored measurement results with date and time are displayed here To access the stored measurement results select the show memory entry and press the I button down...

Страница 10: ...tton down Then select the Yes entry and confirm by pressing the I button downwards The device vibrates briefly to confirm 6 5 3 Date Here you can set the date and time To do this select the Date entry...

Страница 11: ...han 125 standard scale division Nrm Simply delete it again by pressing the I button downwards You can then carry out a new measurement 8 Scope of delivery FLOCK Checker Attachment electrode with prote...

Страница 12: ...en Product Measuring device Type Conductivity meter SCHNIER Part No FLOCK Checker Part No 810523 Handelsbezeichnung FLOCK Checker Function Measuring instrument for determining the conductivity of floc...

Отзывы: