![Schneeberger MINIRAIL Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/schneeberger/minirail/minirail_manual_1213711033.webp)
33
10
MINISCALE PLUS Error Description
Error
Possible Causes
Solution
Resolution is not
achieved
Visible interference
in the measurement
signal
Further errors
Interpolation too low
Evaluation too low
Incorrect input frequency
Incorrect customer-supplied
cable
Further investigation needed
Maximum speed of 3.2 m/s
exceeded
The number on the interface
module does not match the
MINISCALE PLUS carriage
number
The number on the interface
module does not match the
MINISCALE PLUS carriage
number
Increase interpolation
Contact SCHNEEBERGER
Adjust frequency to travelling
speed
Limit the speed to 3.2 m/s
Use digital interface module
and digital input of the USB
counter (caution: maximum
speed 0.2 m/s)
For higher speeds, use the
analog interface module and
analog input (caution: maxi-
mum resolution 0.39 µm)
Check number relationship
between interface module,
carriages and guideways
Use a shielded twisted pair
cable
System must be returned to
SCHNEEBERGER for
adjustment
Adjust as described in
chapter 6.1
Return the system to
SCHNEEBERGER
Repeat evaluation 4 times
Digital interface
module is not
working correctly
Analog interface
module is not
working correctly
If using USB counter: Interpola-
tor has a resolution of just 256,
meaning the displayable
resolution is limited to 0.39 µm.
Digital input has a maximum
input frequency of 500 kHz.
The speed is therefore limited
to 0.2 m/s (or 0.4 m/s) for a
resolution of 0.1 µm.
Incorrect position
during high speeds
when using USB
counter
10 MINISCALE PLUS Err
or Description
www.servo2go.com
www.servo2go.com
Toll Free Phone: 877-378-0240
Toll Free Fax: 877-378-0249
www.servo2go.com