6
Compressor - maintenance
With the following table you can see the service-clearance of the compressor. The service – clearances are given
in operating hours.
Use only synthetic oil for the compressor (Gimaex-Schmitz item-no. #7971), the guarantee becomes void when
using an other oil.
Attention!
When operating in soiled surroundings the oil change should take place more frequent.
Belt tension
Æ
regular
control
(increase the tension when necessary, by moving the
base
plate
)
Change belt
Æ
when
necessary
(Lose screwing of the base plate, change belt, tense belt
by moving the base plate.)
Check oil level
Æ
after every operation
(Oil level approx. center inspection glass)
Oil change
Æ
after 100 operating hours, resp. at least 1 x
Annual
(fill new oil up to top edge inspection glass)
Change oil filter
Æ
after 100 operating hours, resp. at least 1 x
annual
Clean air filter
Æ
after 100 operating hours
Change air filter
Æ
1 x annual
Inspect oil leakage
Æ
after every operation, resp. regular control
Check function of safety valve
Æ
regular
control
Check condition of the hoses
Æ
regular
control
Check strainer in the inclined position valve
Æ
after every operation, resp. regular control
!