9
3.3.2 Switch-On
- Press the ON/OFF key .
The DISPLAY shows
cN
all symbols.
The DISPLAY then momentarily shows the tension range and the software version,
e.g. E 1.0, and subsequently carries out a self test and the zero adjustment (see also
Chapter 3.3.3)
The DISPLAY shows
, the tension meter is now ready to operate.
3.3.3 Switch-Off
Auto power off
:
- The tension meter switches off automatically after 3 minutes of non-use.
Manual switch-off
:
- Press the ON/OFF key 5 for about 5 seconds.
3.3.4 Zero Adjustment of the Measuring Position (Auto Zero)
Zero adjustment is automatically carried out for the current measuring position.
Zero adjustment must be carried out whenever the tension meter does not
display “0” in measuring position.
The process material must not yet be inserted!
Requirement
:
- Tension meter switched on as described in Chapter 3.3.2.
To carry out zero adjustment
:
- Hold the tension meter in the desired measuring position. Be careful to hold the
instrument absolutely steady.
- Press the ON/OFF/ZERO key.
The DISPLAY momentarily shows
0 0 0 0
and then switches to
.
The tension meter is now adjusted for the new material path and is ready to measure.