The device was designed according to the state of the art and the approved safety stan-
dards. Nevertheless, its use may cause serious or fatal injury to the user or third persons, 
and/or an impairment of the device or of other material assets. 
The device may only be applied: 
- For its intended use in a faultless condition with regard to the safety requirements. 
- Malfunctions that could impair safety must be remedied immediately. 
- Personal protective equipment must be used according to the EC Directive 89/686/EEC.

The Operating Instructions must always be kept on hand where the device is operated.
Apart from the Operating Instructions, the generally and locally valid regulations on acci-
dent prevention and environmental protection must be provided and complied with.

1.4  Informal Safety Measures

1.6  Intended Use

1.7  Dangers in Handling the Device

The device is intended exclusively to be used as a Durometer. Any other use or any use 
exceeding this intention will be regarded as misuse. Under no circumstances shall HANS 
SCHMIDT & Co GmbH be held liable for damage resulting from misuse. 
The intended use also includes: 
- Complying with all notices included in the Operating Instructions and observing all  
  inspection and maintenance works.

1.8  Copyright

1.9  Declaration of Conformity

The copyright on these Operating Instructions remains with the company 
HANS SCHMIDT & Co GmbH. 
These Operating Instructions are intended for the operating company and its personnel 
only. They contain instructions and notices that may only be reproduced on the prior  
written permission of 
HANS SCHMIDT & Co GmbH 
and under indication of the complete reference data. Violations will be prosecuted.

Our mechanical durometers do not belong to the EC machinery directive 2006/42/EC and 
do not have a CE mark.

1.5  Training of the Personnel

Only trained and instructed personnel is permitted to work with the device. The responsi-
bilities of the personnel must be clearly defined for mounting, commissioning, operation, 
setup, maintenance and repair. Trainees may only work with the device under the supervi-
sion of an experienced personnel

The device must not be operated in potentially explosive areas and must 

not come into contact with aggressive substances.

Содержание HP Series

Страница 1: ...HP Series Model HP 2 5 HP 5 HP 10 HP 2 5 F HP 5 F HP 10 F Edition HP 05 3 E Instruction Manual Valid as of 01 02 2010 Please keep the manual for future reference S C H M I D T c o n t r o l i n s t r u m e n t s ...

Страница 2: ...eclaration of Conformity 4 2 Available Models 5 2 1 Specifications 5 2 2 Delivery Includes 6 2 3 Unpacking 6 3 Operating Procedure 6 3 1 Notices Before Starting Measurement 6 3 2 Measuring with the Durometer 6 3 3 Verification of Calibration 7 3 3 1 Verify calibration of durometer models HP 2 5 HP 5 and HP 10 7 3 3 2 Verify calibration of durometer models HP 2 5 F HP 5 F and HP 10 F 8 4 Optional A...

Страница 3: ...e device Insufficient inspection of device components that are subject to wear Opening the device or improper repair work Disasters caused by the effects of foreign objects or by force majeure 1 1 Notices within the Operating Instructions The fundamental prerequisite for the safe handling of this device and its troublefree opera tion is the knowledge of the basic safety notices and safety instruct...

Страница 4: ... shall HANS SCHMIDT Co GmbH be held liable for damage resulting from misuse The intended use also includes Complying with all notices included in the Operating Instructions and observing all inspection and maintenance works 1 8 Copyright 1 9 Declaration of Conformity The copyright on these Operating Instructions remains with the company HANS SCHMIDT Co GmbH These Operating Instructions are intende...

Страница 5: ... on measuring the resistance force of the penetration of a ball sensor into a bobbin under a constant spring load This principle is based on the Shore hardness test procedure The display range of the textile durometers covers a range from 0 to 100 units where 0 corresponds to the minimum and 100 to the maximum hardness value These units have no formal industry standards or engineering classificati...

Страница 6: ...s that the same amount of pressure is applied from measurement to measurement and pre vents measuring errors Record the reading after approx 3 sec onds The hardness scale covers a range from 0 to 100 where 0 corre sponds to the minimum and 100 to the maximum hardness value Each test sample has to be tested in at least three different points Durometer Operating manual Specific Test Report 2 1 as pe...

Страница 7: ...aged by pressing the flat bot tomed models F models against a smooth level surface such as glass or marble When fully pressed down the scale pointer should make one full turn on the scale from zero to zero The scale pointer should return to the initial zero position when you release pressure If it does not return the instrument to the manufacturer for servicing On models with a concave base for me...

Страница 8: ... pointer should make one full turn on the scale from zero to zero If the result of verification is positive the durometer should show correct readings Models HP 2 5 F HP 5 F and HP 10 F Scale Glass plate Outer shell Color marking Holding screws fig 3 3 2 Do not loosen the holding screws of the movement under any circumstanc es Loosening these screws may alter the calibration of the instrument ...

Страница 9: ...s to zero the memory pointer remains in position marking the highest reading PEAK of the measurement 4 Optional Accessories Memory Pointer Option Code M Test Stand Model PSHP for serial testing Spring loaded lever for easy use Height adjustable from 0 to 200 mm Travel of operating lever 40 mm Dimensions LxWxH 162 x 100 x 320 mm Net weight approx 2 3 kg Base plate and prisms optionally available pl...

Страница 10: ...10 ...

Страница 11: ... the user s experience Assuming normal operating time and load as well as careful handling of the hardness tester we recommend a verification interval of 1 year 8 Correspondence Should you have any questions regarding the tension meter or Operating Instructions or their use please indicate above all the following details which are given on the ID plate 1 The tension meter model 2 The serial number...

Страница 12: ...one int 49 0 8638 9410 0 Fax int 49 0 8638 4825 int 49 0 8638 67898 e mail info hans schmidt com Internet http www hans schmidt com Tension Meter Force Gauge Torque Meter Tachometer Speed and Lengthmeter Electronic Lengthmeter Stroboscope Screen Printing Tension Meter Thickness Gauge Yarn Package Durometer and Shore A Durometer Sample Cutter Balance Moisture Meter Leak Tester Softometer More than ...